XAG RevoCast 2.0 P100 Скачать руководство пользователя страница 3

www.xa.com

1

Safety Guidelines

•      XAG RevoCast 2.0 P100 Version (Model: M4RC-60B-P) is only compatible with XAG P100 Agricultural 

Drone. Do NOT use it on other products or for non-agricultural purposes.

•     RevoCast system only works with dry granules - nonsticky ones will be good - with a diameter of 1 to 6 

mm.

•     Do NOT use nonstandard granules as they may affect operations, or even cause damage to the 

RevoCast system. Please follow the application instructions for the granules exactly when you use 

them.

•     It is advisable to use the product on sunny, cloudy or overcast days with winds of force 3 or below in 

an area free of strong electromagnetic interference.

•     NEVER use the product in adverse weather conditions including rain, snow, frost, fog, thunder, hail, 

dust storm and gale or in an area with strong electromagnetic interference.

•     Please install and use the product in strict accordance with this User Manual.

•     Before operation, please ensure that the spraying bars have been removed to avoid damage caused 

by the throwing granules.

•     Before each operation, check if the feeding motor, spreading disc motor and radar level sensor are 

working properly. Calibrate with the granules to be spread.

•      It is NOT allowed to use a non-XAG granule container, covert the container on your own or increase its 

capacity in that it may result in malfunctions, inefficient operations, or damage to the product, which 

are not covered by the warranty. User shall solely assume the liabilities for any loss arising therefrom, 

both financially and legally. 

•     During operation, pay attention to the remaining granules and return for replenishment when they are 

running out.

•     Be careful during operation. Do NOT touch the running feeding motor or spreading disc motor to 

avoid injury.

•      Do NOT stay near or touch the operating aircraft and RevoCast system to avoid bodily injury.

•      Please empty the granule container after operation. Turn off the power and rinse the container, 

feeding tube, spreading discs and radar level sensor with clean water to remove residual granules. 

Then air-dry the RevoCast system in a cool place away from direct sunlight.

•    NEVER wash the RevoCast system when the power is on.

•     NEVER store granules in the container, or they might cake when getting damp, thus affecting motor 

starting or feeding precision.

•     NEVER leave granules in the spreading discs for a long time to prevent granules from sticking to the 

vanes, which may affect spread width.

•     Please fully clean and check the product to make sure there is no blockage or other malfunctions 

when not in use. Store it in a dry, cool, and safe place.

•     Accessories provided by non-XAG manufacturers are NOT allowed for use or repair as they may 

seriously affect the safety and service life of XAG's products. The warranty does NOT cover any damage 

to the product caused by using such accessories.

Содержание RevoCast 2.0 P100

Страница 1: ...XAG RevoCast 2 0 P100 Version User Manual EN Version 1 0...

Страница 2: ...ty purposes and better user experience it is highly recommended that you read this manual carefully and strictly follow the instructions hereof Contact Us If you have any questions about this document...

Страница 3: ...esult in malfunctions inefficient operations or damage to the product which are not covered by the warranty User shall solely assume the liabilities for any loss arising therefrom both financially and...

Страница 4: ...in aquaculture thus offering intelligent precision efficient and flexible production solutions List of Items Please see that all of the following items are present when unpacking the box Should there...

Страница 5: ...f residual soapy water or the laundry powder water mixture in the RevoSpray system Place the empty liquid tank in the aircraft and start spraying until all tubes are drained avoiding dam age to other...

Страница 6: ...t System Lift the airframe place it onto the RevoCast system and line up the holes on the bottom of the airframe with the bosses on the top of the RevoCast system Boss Slot Spraying Bar Quick Release...

Страница 7: ...ock the hasp on the airframe to the hook on the RevoCast system Connect Cables Connect the mount cable and the RevoSpray cable Affix them to the cable holder under the battery compartment RevoCast Cab...

Страница 8: ...the hasps of both quick release units Remove the quick release units rinse them off and air dry them in a cool place away from direct sunlight Hasp Spreading Disc Signal Cable Quick Release Unit Open...

Страница 9: ...lot pipe surface cross axle and guide rail are clean and free of foreign matters Align the guides with the guide rails and insert the quick release unit into the RevoCast system in the same direction...

Страница 10: ...e Specifications Model M4RC 60B P Compatible with XAG P100 Agricultural Drone Dimensions 983 873 573 mm Net Weight 13kg Rated Capacity of Granule Con tainer 60L Rated Payload of Granule Contain er 40k...

Страница 11: ...s pertaining to vend ibility fitness for a particular use or non infringement 06 To the maximum extent permitted by law XAG shall not be liable for all losses caused by your im proper operation Also X...

Страница 12: ...s and processes etc belongs to Guangzhou Xaircraft Technology CO LTD and is protected by copyright law Without written authorization no individual or institution is allowed to reproduce extract transl...