X10 DC8700P Скачать руководство пользователя страница 13

25

24

was NOT flashing, the sensor is logged
into the next sequential zone (instead
of the same zone it was in).

To avoid this, remove the old batteries
and wait at least 4 hours before installing
the new batteries.

Motion Sensors

If any if the Console's zone indicators
flash slowly, the Motion Sensor or Door/
Window Sensor (see previous section)
for that zone has not reported in during
the last four hours. This is most likely
caused by dead batteries.

After  Replacing  the  batteries  in  the
Motion Sensor, the following steps are
necessary  to  determine  that  the
Console still recognizes it.

1. Place  the  slide  switch  under  the

SETUP flip door to RUN1 or RUN2.

2. Press 

TEST 

on the Motion Sensor.

If  the  appropriate  zone  indicator
blinks, then the Console recognized
the  Motion  Sensor  and  no  further
action is necessary.

If  the  zone  indicator  didn't  blink
when you pressed TEST:

1. Place  the  slide  switch  under  the

SETUP flip door to INSTALL.

2. Press 

TEST 

on the Motion Sensor.

The Motion Sensor transmits a code
to  the  Console.  The  console
acknowledges this with a beep and
logs in the Motion Sensor.

Console

The console’s backup battery allows the
system to work during a power outage.
The 

BATTERY  LOW

  indicator  on  the

console lights when you need to replace
the backup batteries.

Installed sensors, and Central Station
phone numbers are stored in Electrically
Erasable  Programmable  Read  Only
Memory (EEPROM) which will not lose
its data even if the power is out and the
battery is dead.

Four  AA  alkaline  batteries  provide  at
least 12 hours of backup. Replace the
batteries at least once a year.

To  remove  all  sensors

 

and

remotes  from  the  console's
memory:

• Set the console to INSTALL.

• Press 

PANIC

ARM HOME

 and 

ARM

AWAY

 at the same time.

N o t e :

  Telephone  numbers  and

configuration data downloaded by the
service center (such as entry and exit
delays etc.) cannot be erased, and can
only  be  changed  on  request  by  the
service center.

Security Remote Controls

For the Keychain Remote use two AAA
alkaline batteries.

For  the  Security/Home  Automation
Remote use four AAA alkaline batteries.

After replacing batteries, the following
steps are necessary to determine that
the console still recognizes the remote
control.

1. Place the console slide switch under

the SETUP flip door to 

RUN2

.

2. Press 

ARM

 on the Remote Control.

If  the  system  arms,  the  Console
recognized the Remote Control and
no further action is necessary.

If the system did not arm:

1. Place  the  slide  switch  under  the

SETUP flip door to 

INSTALL

.

2. Press 

ARM

 on the Remote Control.

The  Remote  Control  transmits  a
random  code  to  the  console.  The
Console acknowledges this with a
beep  and  logs  in  the  Remote
Control. If you do not hear a beep
follow the instructions on page 8 to
re-initialize the remote.

Home Automation Remote
Control

The Home Automation Remote Control
uses four AAA alkaline batteries but it
does not require any installation. Just
set  its  House  Code  dial  to  match  the
Console and it's ready to use.

Door/Window Sensors

If any of the Console's zone indicators
flash slowly, the Door/Window Sensor
or Motion Sensor (see next section) for
that zone has not reported in during the
last four hours. This is most likely caused
by dead batteries.

After replacing the batteries in the Door/
Window Sensor, the following steps are
necessary  to  determine  that  the
Console still recognizes it.

1. Place the console slide switch under

the SETUP flip door to 

RUN2

.

2. Press 

TEST 

on  the  sensor.  If  the

Door/Window  sensor  LED  flashes
and  the  console  chimes,  it
recognized  the  sensor  and  no
further action is necessary.

If you didn't hear a chime when you
pressed TEST:

1. Place  the  slide  switch  under  the

SETUP flip door to 

INSTALL

.

2. Press and hold 

TEST 

for 3 seconds

then  release  it.  The  Door/Window
Sensor LED flashes twice.

3. Press 

TEST

  again.  The  Door/

Window Sensor transmits a code to
the  Console.  The  console
acknowledges this with a beep and
logs in the code.

The Door/Window Sensor will normally
be logged into the SAME zone number
as  it  was  before  you  replaced  the
batteries. However,  if  you  replace  the
battery in the sensor when its zone light

REPLACING BATTERIES

Содержание DC8700P

Страница 1: ... O C G K INSTANT DELAY BRIGHT DIM ENTRY DOOR WINDOW SENSOR MOTION DETECTOR Lamp Module A I E M O C G K 1 9 5 13 15 3 7 11 UNIT HOUSE BATTERY ARM DISARM LIGHTS ON LIGHTS OFF PANIC Monitored Security System Model DC8700P Monitor Plus ARM AC POWER MONITOR BATTERY LOW ZONES 1 9 2 10 3 4 5 6 7 8 11 12 13 14 15 16 BYPASS ON LIGHTS OFF ZONES 9 16 PANIC AWAY ARM HOME ...

Страница 2: ...l the RENs If the total is more than five your telephones might not ring In rural areas a total REN of three might impair ringer operation If ringer operation is impaired remove one of the devices from the line Note You must not connect your console to Coin operated systems Party line systems Most electronic key telephone systems Your console s telephone dialer complies with Part 68 ofFCC Rules Yo...

Страница 3: ...requency Built in Digital Communicator Calls the monitoring station in the event of a break in Fully expandable You can protect up to 16 zones with your security system plus you can control lights and appliances by Remote Control to start a complete home automation system Panic Alarm Lets you sound the alarm without calling the monitoring station Automatic lighting control When the Monitor Plus Se...

Страница 4: ...her end of the cord is plugged into the telephone device If you already have a phone plugged into the jack use the included T adapter to plug the console and telephone into the same jack If your telephone wiring does not have a modular jack you can Update the wiring yourself Most good electrical stores sell adapters to convert older wiring methods to modular wiring Have the telephone company updat...

Страница 5: ...e switch back to RUN1 or RUN2 Note If you do not hear a tone press the CODE button located on the front under the label with a pencil then reinstall the remote as described above PANIC PANIC ARM DIS HOME ARM ARM DIS AWAY ARM SECURITY LIGHT ON OFF A I E M O C G K INSTANT DELAY BRIGHT DIM ENTRY 4 Set the console s slide switch back to RUN1 or RUN2 5 To set up additional key chain remote controls up ...

Страница 6: ...oRUN2 located under the flip up door 2 Open the door or window The light on the sensor blinks the console chimes and the zone light for the sensor lights If the light on the sensor does not blink and the console doesn t chime check that the Door Window Sensor magnet and switch are correctly aligned with the arrows facing each other Typical Door Window Sensor mounting methods 4 Press TEST again The...

Страница 7: ...itializes each Motion Sensor just like you initialize Door Window Sensors Each Motion Sensor will be assigned to one of the 16 zones 1 Install four AA alkaline batteries in the battery compartment on the front of the Motion Sensor batteries sold separately Note Place the Motion Sensor face down so that it doesn t see anything during installation Otherwise if it is sees motion it might be installed...

Страница 8: ... remote controls NOTE Follow the installation instructions included with the Wall Switch Module sold separately Set the House Code and Unit Code to A 13 or other codes on request from the monitoring station see page 18 if you want the lamp to flash during an alarm Remote Switch 1 9 5 13 A I E M All types of Motion Sensors sense motion by detecting a change in temperature Therefore to help prevent ...

Страница 9: ... to do is Fill out the enclosed monitoring agreement and mail or fax it to ORCA Monitoring Services Call ORCA Monitoring Services at 1 800 FOR ORCA 1 800 367 6722 and follow the instructions to have your system initialized Note Although you can register your system as soon as it has been installed the Monitoring Station will not respond to alarm calls until the signed monitoring agreement has been...

Страница 10: ...tivate USING THE SYSTEM Calling Customer Service After you have registered your system you can easily call the customer service center if you need help or to change any of the default options as follows Set the Base Console slide switch to RUN1 or RUN2 Press the MONITOR button The console automatically dials the customer service number Pick up the handset of a phone connected to the same line as t...

Страница 11: ...ls the monitoring station The delay can be changed by the service station 3 PressDISARM to stop the siren The lights remain on Self checking system All Door Window Sensors and Motion Sensors report in to the Console every 90 minutes If the Console does not receive a signal from the sensor within four hours it reports a problem with that sensor by slowly flashing the appropriate zone indicator If y...

Страница 12: ...the panic alarm trips the alarm but will not call the monitoring station unless you arm the system first This option can be changed by the service station To trigger the panic alarm Press PANIC on the Security Home Automation Remote Control or press ARM and DISARM together on the Keychain Remote PressDISARM to cancel the alarm Trouble Alarm If you hear a repetitive trouble alarm when you try to ar...

Страница 13: ...chain Remote use two AAA alkaline batteries For the Security Home Automation Remote use four AAA alkaline batteries After replacing batteries the following steps are necessary to determine that the console still recognizes the remote control 1 Place the console slide switch under the SETUP flip door to RUN2 2 PressARM on the Remote Control If the system arms the Console recognized the Remote Contr...

Страница 14: ...e Check that the battery indicator on the Remote Control comes on when you press a button Replace batteries and reinstall remote if necessary Lights will not turn on or off from the LIGHT ON or LIGHT OFF buttons on the Remote Control TROUBLESHOOTING PROBLEM SOLUTION Check that the slide switch under the SETUP flip door is set to RUN1 or RUN2 Check that the red indicator on the Remote Control turns...

Страница 15: ... remove the batteries wait a few seconds then replace the batteries Press CODE then press ARM again SOLUTION PROBLEM You open a door or window and the alarm does not trip Check that the system is armed Be sure the slide switch under the SETUP flip door is in the RUN1 or RUN2 position Check to see if the alarm trips when you pressTEST on the Door Window Sensor If the alarm does not trip when you pr...

Страница 16: ...es which zone was violated To turn the zone indicator off and stop the armed indicator from flashing press the LIGHT ON or LIGHT OFF button on the remote control If a zone indicator is not on the violated zone will have been one of the second eight zones Press BYPASS to see which zone was tripped If thePOWERHORN does not trip when the alarm trips Be sure you set the Housecode on thePOWERHORN to th...

Страница 17: ... CAREFULLY THIS WARRANTY DOES NOT EXTEND TO ANY X10 PRODUCTS WHICH HAVE BEEN SUBJECT TO MISUSE NEGLECT ACCIDENT INCORRECT WIRING OR TO USE IN VIOLATION OF OPERATING INSTRUCTIONS FURNISHED BY US NOR EXTEND TO ANY UNITS ALTERED OR REPAIRED FOR WARRANTY DEFECT BY ANYONE OTHER THAN X10 THIS WARRANTY DOES NOT COVER ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED...

Отзывы: