- 5 -
HOT AIR GUN
1. The top display will show “SLP” when the hot air gun is in its holder
and in sleep/standby mode.
2.
Push the Hot Air Temperature Adjustment Buttons (▲ or ▼ ) in the
middle unit to set the hot air gun temperature. The hot air gun can
be set between 212°F ~ 932°F / 100°C ~ 500°C.
3. Turn the Air Flow Control Knob to adjust the airflow for the hot air
gun. This can be set from 20 - 100.
CAUTION
When using a temperature higher than 300°C on the hot air gun the
air flow should be set at 45 or higher. This will prevent damage to
the hot air gun and increase the life of the heating element.
4. When the hot air gun is removed from the holder it will start
blowing air and ramp up to the programmed temperature and air
speed quickly.
5. When the hot air gun is not in use always place it back in the side
holder or in the vertical position in the upright tower holder. When
the hot air gun is placed in one of these holders, it will start going
into the Auto Cool Down and Sleep/Standy mode immediately. The
hot air gun will continue blowing air until the temperature gets back
down to 100°C and then the airflow will stop and the hot air gun will
go into sleep/standby mode.
Note:
When the hot air gun is initially returned to either of these holders,
the air flow may increase noticeably while the hot air gun is
cooling down and going into sleep/standby mode. This is a safety
feature built into the unit.
6. When the hot air gun is removed again from either of these holders
it will start blowing air and ramp up to the programmed temperature
and air speed again quickly.
7. To turn the hot air gun off, turn off the
II
power switch on the front
of the unit.
Note:
Do not unplug the unit or shut off the Main Power Switch on
the back of the unit until you have placed the hot air gun in the
holder and it has cooled down and the air has stopped blowing
automatically - this allows a full cool down of the hot air gun.
When the unit is not in operation and has fully cooled down, turn the unit
off with the power switch located on the back of the unit and unplug from
the outlet.