- 3 -
FUNCTION SETTINGS
FAHRENHEIT / CELSIUS CONVERSION
1. Turn off the power switch.
2. Press and hold the “+” button while turning the power switch on.
The display will show “F” for Fahrenheith display mode.
3. Press the “-” button to select “C” (Celsius) or “+” button to select “F”
(Fahrenheit).
4. Wait for approximately 4 seconds and the program will save
and exit on its own. The temperature display will then show the
temperature measurment being used.
SLEEP TIMER
1. Turn off the power switch.
2. Press and hold the “-” button while turning the power switch on. The
display will show “LXX” (where XX is the number of minutes the iron
must be still for the iron to go into sleep mode).
3. Press the temperature “+” or “-” to adjust the sleep timer. This can
be set anywhere from “00” (where the sleep timer will NEVER turn
on) to “99” (where the sleep timer will turn on after 99 minutes of
inactivity).
Note: Selecting L00 can greatly reduce the life of your soldering iron
and heating element.
4. Wait for approximately 4 seconds and the program will save and
exit on its own.
TEMPERATURE CALIBRATION
1. Turn on the power switch.
2. Press and hold both the “+”and “-” buttons until the display flashes
“CAL”. This indicates you are now in Calibration Mode.
3. While the display is flashing, press “+” or “-” to input the tested
temperature.
4. Wait for approximately 4 seconds and the program will save and
exit on its own.