background image

- 3 -

FUNCTION SETTINGS

FAHRENHEIT / CELSIUS CONVERSION

1.  Turn off the power switch.

2.  Press and hold the “+” button while turning the power switch on. 

The display will show “F” for Fahrenheith display mode.

3.  Press the “-” button to select “C” (Celsius) or “+” button to select “F” 

(Fahrenheit).

4.  Wait for approximately 4 seconds and the program will save 

and exit on its own. The temperature display will then show the 

temperature measurment being used.

SLEEP TIMER

1.  Turn off the power switch.

2.  Press and hold the “-” button while turning the power switch on. The 

display will show “LXX” (where XX is the number of minutes the iron 

must be still for the iron to go into sleep mode).

3.  Press the temperature “+” or “-” to adjust the sleep timer. This can 

be set anywhere from “00” (where the sleep timer will NEVER turn 

on) to “99” (where the sleep timer will turn on after 99 minutes of 

inactivity).  

Note: Selecting L00 can greatly reduce the life of your soldering iron 

and heating element.

4.  Wait for approximately 4 seconds and the program will save and 

exit on its own.

TEMPERATURE CALIBRATION

1.  Turn on the power switch.

2.  Press and hold both the “+”and “-” buttons until the display flashes 

“CAL”. This indicates you are now in Calibration Mode.

3.  While the display is flashing, press “+” or “-” to input the tested 

temperature.

4.  Wait for approximately 4 seconds and the program will save and 

exit on its own.