PUMP NOT INFLATE/GAUGE NOT REGISTER

 

1.

 

There are two ports on the pump, IN and OUT. Make sure you use the OUT port on the handle to 

inflate.

 

2.

 

Do not bend too much when connecting the pipe to the valve, otherwise the pipe will easily fall 

off

 the valve. Please try to keep the 

vertical connection.

 

3.

 

Check the pump gauge. Make sure the hose is detached. Pull up the pump handle. Block the OUT port with one hand, and then push 

the handle down with the other hand. You should feel resistance, and the gauge pointer should move. If you don't feel resistance, then 
the pump is leaking air. If you feel resistance, but the pointer does not move, the gauge is defective.

 

 

FIN FALL OFF

 

1)

 

Press the clip down fully to lock the 

n.

 

2)

 

There is a screw underneath the clip. Tighten the screw to secure the installation.

 

 

 

LEAK

 

1)

 

HIGH PRESSURE VALVE LEAKING

 

If the board is losing pressure check the board for leaks starting with the high-

pressure valve, Inflate the board to around 7 psi and 

spray 

the valve area with water, Check and see if there are air bubbles.

 

If leak is identified, deflate the board (a) and tighten the valve using the supplied wrench in the repair kit, Insert the wren

ch into the valve 

and rotate clockwise (b), After tighteni

ng, Inflate the board to check if leaking is fixed.

 

 

(a)

 

(b)

 

If tightening the valve does not fix leaking, the valve needs to be replaced. Take out the defective 
valve using the wrench to rotate counterclockwise. Install a new valve and check if leaking is fixed

.

 

 

 

2)

 

SMALL PUNCTURE LEAKING

 

If leak is not found at the valve, you may have a small puncture.

 

Small punctures-can be easily found by spraying all around the board to see where air bubbles 

become visible. If you can't find any bubbles, inflate the board to 15 

psi and listen for an air leak. 

Note that for the repair to be successful, the humidity level should be less than 60%, temperature 
between 18

°C/

25

°C o

r 65F/77F . Avoid carrying out repairs in the rain or in direct sunlight.

 

1)

 

Draw the shape of the patch exactly where it will be applied, cut a round patch at least 1 cm/l/2" larger than the cut/damaged area.

 

2)

 

Clean the damaged area and the corresponding side of the patch with a grease remover and allow it to dry for 5 minutes.

 

3)

 

Apply 3 thin layers of glue on both the damaged area and the patch and allow each layer to dry for 5 minutes until the glue feels tacky. 

TROUBLESHOOTING

 

Содержание MAUI

Страница 1: ...www x rock co uk instagram xrock_sup OWNER S MANUAL www x rock co uk instagram xrock_sup 320x80x15cm ALL AROUND INFLATABLE STAND UP PADDLE BOARD ...

Страница 2: ...disassembly Operation instruction Troubleshooting Warranties To ensure safety and prevent tragic accidents please read it carefully and familiarize yourself with the product before using it The cautions and warnings below are advisories relative to various types of situations Please read them before you use the product DEAR CUSTOMER WARNING CAUTION DENOTES AN IMMINENT HAZARD WHICH WILL RESULT IN S...

Страница 3: ...ers Avoid paddling in off shore winds or windy conditions Be sure not to exceed your paddling ability and beware of your limits Be aware of changing weather conditions Do not use alcohol or mind altering drugs while using this product Never use this product in dark without proper lighting Never let a minor use the board without adult supervision Before going on a long paddle be sure to inflate your ...

Страница 4: ...action hand pump One 10 ft coiled leash One storage and carry backpack One repair kit glue is to be purchased separately MODEL LENGTH WIDTH THICKNESS WEIGHT VOLUME LOAD 320x80x15CM 10 6FT 320CM 31IN 80CM 6IN 15CM 18 7LB 8 5KG 275 L 297LB 135 KG 1 CARRY HANDLES 2 BUNGEE CORD 3 D RINGS 4 EVA PAD 5 AIR VALVE 6 CENTER FIN 7 SIDE FINS IN THE PACKAGE TECHNICAL SPECIFICATION 5 4 1 2 3 3 6 7 x2 ...

Страница 5: ...ation disconnect the hose and close the cap The valve won t be airtight until the valve cap is closed 3 Read the instructions on the pump body about single action pumping and double action pumping First pump in double action mode to generate large volume of air at low pressure When you feel pumping becomes heavy switch to single action and inflate to the desired pressure Check board pressure with t...

Страница 6: ... valve Pump till the board is fully deflated detach the hose push the valve pin to close the valve and then close the cap STORAGE 1 Clean and check the board and all the accessories after each use Rinse it thoroughly with clean water and make sure to remove any residues or salt if used in salt water Do not use detergents or any type of silicone based products Make sure the product is completely dry...

Страница 7: ... rotating in as paddle comes in line with your body 7 Tomake a wide turn keep paddling on one side without switching Tomake a narrow turn place your paddle near the tail of the board and pull forward whilst shifting your torso to the desireddirection SOME TIPS FOR BEGINNERS Look forward horizontally Do not look into the water Keep paddling Your paddle is another supporting point for keeping balanc...

Страница 8: ...ed deflate the board a and tighten the valve using the supplied wrench in the repair kit Insert the wrench into the valve and rotate clockwise b After tightening Inflate the board to check if leaking is fixed a b If tightening the valve does not fix leaking the valve needs to be replaced Take out the defective valve using the wrench to rotate counterclockwise Install a new valve and check if leaking i...

Страница 9: ...ons listed below Boards purchased in used condition Boards used in rental commercial or teaching environment Damage or defects caused by impact with any materials or objects such as rocks docks other boards etc Damage or defects caused by use outside of its intended purpose Damage or defects caused by normal wear and tear Damage or defects caused by transport loading unloading dropping or out of w...

Отзывы: