MAINTENANCE 

Cleaning

 

An accumulation of dust, dirt, etc. will decrease the intensity of the light and also change the quality of the illumination. 
Therefore, the fixture must be cleaned periodically. 

1.  Turn the fixture off. 

2.  Remove the diffuser as indicated in "Removal of Diffusers". 

3.  Wash the glass (or acrylic) lenses with soap and water, and thoroughly rinse and dry. 

4.  Clean the housing with a dampened cloth containing mild soap. 

5.  Wipe the lamps and reflector with a clean, white, lint-free cloth. 

6.  Replace the diffusers. 

Removal and Replacement of Components

 

Removal of Diffusers

 

1.    Push one lens slightly off of the flanges of the housing. Tilt slightly to provide clearance of the flanges and lower the lens 

out of the housing. Repeat this step for the second lens. 

Note:  

The lens should always be inserted with the smooth side facing inside of the fixture and the prismatic (textured) 
side facing the outside of the fixture. Orient the lens so that the longest side is parallel to the longest side of the 
luminaire. 

Replacement of Lamps

 

Replace lamps at approximately 75 percent of their rated life expectancy to retain spectral characteristics. Replace burned 
out lamps immediately in order to maintain the overall performance standards of the fixture. 

 

Lamp Replacement Schedule

 

 

Lamp

 

Number of 
Hours

 

F40T12/EX 

5,000 

Examolite TC-440B 

33WA19/EX 

2,000 

F40T12/75 

5,000 

F40T12/65 

5,000 

F40T12/50 

5,000 

F40T12/CW 

12,000 

Examolite SD-840B 

and 

Prooflite PLD 

60WA/IF 

2,000 

Note:   

You do not have to remove the diffusers when replacing lamps. Carefully slide one lens on top of the other for 

lamp replacement. 

Removal of Reflector

 

After removing diffusers and lamps from the housing, remove the reflector by loosening the screws and lowering the 
reflector out of the housing. Flex the reflector slightly inward to allow it to clear the flanges on the sides of the housing. With 
reflector removed, ballasts, lamp sockets, and associated wiring are accessible. 

Replacement of Ballasts, Lamp Sockets, and Associated Wiring

 

Have a professional electrician remove the reflector to expose the wireway and replace ballasts, lamp sockets, and 
associated wiring. 

Содержание Examolite SD-840B

Страница 1: ...d operation KEEP INSTRUCTIONS Retain these instructions for future reference Once you have read these instructions keep them available for other operators to read OBEY ALL WARNINGS Please comply with all warnings and safeguards in these instructions They have been written to keep you and your fixture safe CHOOSE PROPER POWER SOURCES Use the proper power source If you have any doubt consult the lab...

Страница 2: ...aires are designed for 100VAC 50Hz 117VAC 60Hz 220VAC 50Hz 240VAC 50Hz or 277VAC 60Hz operation In all cases proper input power is marked on the box and fixture label CAUTION Do not operate fixture on DC input power Fixture Power Consumption Examolite TC 440B 368 watts Examolite SD 840B 552 watts Prooflite PLD 4 lamp fixture 184 watts Prooflite PLD 8 lamp fixture 368 watts Note Prooflite Models PL...

Страница 3: ...ecific electrical needs 6 If you are mounting the fixture into a standard grid ceiling follow the accepted mounting practices for your building code If the fixture is to be chain hung over a work surface follow CHAIN HUNG MOUNTING PROCEDURE on page 4 7 Wire the fixture using the procedure described in WIRING THE FIXTURE on page 5 8 Peel off the protective blue film on the reflector It is only used...

Страница 4: ...er Fixture Net Weights Proof lite PLD 4 lamp 57 5 lbs 25 87 kg Prooflite PLD 8 lamp 68 0 lbs 30 6 kg Examolite TC 440B 78 0 lbs 35 1 kg Examolite SD 840B 90 0 lbs 40 5 kg On the rear of the fixture housing there are two sets of weld nuts both standard and metric Install the four eyebolts supplied into the standard weld nuts A chain user supplied can then be hooked to the eyebolts and used to suspe...

Страница 5: ...d PLD 840 Dual Source 2 Sets of 4 Fluorescent 4 Ballasts 2 Inputs Ballast 1 Lamps 1 and 3 Ballast 2 Lamps 2 and 4 Ballast 3 Lamps 5 and 7 Ballast 4 Lamps 6 and 8 Black leads for ballasts 1 and 3 go to black AC power input on first AC source White leads for ballasts 1 and 3 go to white AC power input on first AC source Black leads for ballasts 2 and 4 go to black AC power input on second AC source ...

Страница 6: ... is parallel to the longest side of the luminaire Replacement of Lamps Replace lamps at approximately 75 percent of their rated life expectancy to retain spectral characteristics Replace burned out lamps immediately in order to maintain the overall performance standards of the fixture Lamp Replacement Schedule Lamp Number of Hours F40T12 EX 5 000 Examolite TC 440B 33WA19 EX 2 000 F40T12 75 5 000 F...

Страница 7: ... incandescent lamps Dimensions Length 48 in 121 19 cm Width 23 75 in 60 3 cm Height 8 in 20 3 cm Weight 78 0 lbs 35 4 kg 90 0 lbs 40 8 kg Power Consumption 368 watts 552 watts Electrical Requirements 100VAC 50HZ 117VAC 60HZ 220VAC 50HZ 240VAC 50Hz Prooflite Model PLD 440 PLD 840 Single Source PLD 840 Dual Source Light Sources 7500K D75 6500K D65 5000K D50 7500K D75 6500K D65 5000K D50 7500K D75 65...

Страница 8: ...t 8 incandescent lamps are required for each overhead fixture Lamps are sold in packages of sixteen 16 or as part of a specific lamp kit Examolite SD 840B 5000K Replacement Lamp Kit A LK ESD8450 This kit consists of four 4 F40T12 50 X Rite seven 7 phosphor fluorescent daylight lamps four 4 F40T12 CWF lamps and eight 8 60WA IF incandescent lamps Four 4 of each fluorescent lamps and eight 8 incandes...

Страница 9: ... not be liable for errors contained herein or for incidental or consequential damages in connection with the performance or use of this material This manual as well as any revisions are the copyright of X Rite Any reproduction of the publication in whole or in part without the express permission of X Rite is a breach of this copyright Examolite and Prooflite are registered trademarks of X Rite Inc...

Страница 10: ...37 or 1 616 803 2705 Corporate Headquarters Europe Althardstrasse 70 8105 Regensdorf Switzerland Phone 41 44 842 24 00 Fax 41 44 842 22 22 Corporate Headquarters Asia Room 808 810 Kornhill Metro Tower 1 Kornhill Road Quarry Bay Hong Kong Phone 852 2 568 6283 Fax 852 2 885 8610 Please visit www xrite com for a local office near you ...

Отзывы: