D T P 3 2 H S   D E N S I T O M E T E R  

 

15

Operational Considerations Between a DTP32R and a DTP32HS 

 
The DTP 32HS is a “drop in replacement” for the X-Rite DTP32R (R for reflective) strip 

reading densitometer. 
 
There are a few differences in 

operation of the DTP32HS 
compared to the DTP32. The DTP32 

(see diagram at right) has a 
display, keyboard, and strip guide. 

The DTP34HS does not.  In order to 
use the DTP34HS product where a 

software application expects the 
DTP32 product, please consider the 
following. 
 
 
 
 
 
 
 

Operation 

Below we list some of the ways that the use of the instruments will differ. The items in 

italic

 

are phrases often indicated in the host software for the DTP32R. 

 

Use of the strip guide

 – Insert strip at X

 

 

The DTP32R has a strip guide mechanism that ranged numerically from 5 to 30. Some 

software packages indicate a setting for this guide. These prompts can be ignored with the 
DTP32HS as no guide is required.

 

 

Using the keyboard – 

Push Key #X

 

The DTP32R has four keys to control the menus found on the LCD. The DTP32HS does not 

require unique key sequences, because it is software driven, therefore these prompts can 
be ignored.  

 

 

Calibration of the instrument – 

Go to page 2 to Calibrate

 

The DTP32HS can be calibrated without using menus, as is required for the DTP32 product. 
A calibration can be initiated like any other reading. Please see the calibration section in the 

manual for a full explanation.  

X-Rite DTP32R AutoScan 

Paper and Film 

Entrance

Cal Strip and 35mm 

Film Entrance

Paper and Film Guide

Keyboard

Display

AC Adapter Input 

Serial 
Interface 
Connection 

Содержание DC240 - DocuColor 240 Color Laser

Страница 1: ...DTP32HS Auto Scanning Densitometer Operator s Manual ...

Страница 2: ......

Страница 3: ...ets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada Equipment Information Use of this equipment in a manner other than that specified by X Rite Incorporated may compromise design integrity and become unsafe WARNING This instrument is not for use in explo...

Страница 4: ...instrument This agreement shall be interpreted in accordance with the laws of the State of Michigan and jurisdiction and venue shall lie with the courts of Michigan as selected by X Rite Incorporated Table of Contents Overview and Setup 3 Instrument Description 3 Unpacking and Inspection 3 Instrument Interface 4 Instrument Location Requirements 5 Strip Feeding Requirements 5 Instrument LED Indicat...

Страница 5: ...rip Reading Densitometer reflection versions it will by default report itself as a DTP32R Most existing software packages will reference a DTP32R in their connection menu while newer software may use DTP32HS Select DTP32HS if it is available otherwise select the DTP32R Unpacking and Inspection After removing the instrument from the shipping carton inspect it for damage If any damage has occurred d...

Страница 6: ...Connect the interface cable as shown CAUTION Use only the 100 240VAC input 12VDC output Switching Power Supply to power the instrument 3 Plug the small end of the switching power supply into the power input connector of the interface cable 4 Plug the detachable line cord into the power supply and then into the AC wall receptacle The instrument does not have an ON OFF switch PC DB9 AC Wall Receptac...

Страница 7: ...complete list of conditions reported by the LED Operation Mode Solid Green self test passed and instrument is ready for use with defined strip Slow Flashing Green strip reading in progress strip being read or ready for next pass multi pass strip definition Fast Flashing Green strip reading was attempted but the wrong strip was read or strip was skewed during reading Slow Flashing Amber Green a con...

Страница 8: ...0 75 19mm to the left of the alignment mark optical path when measuring This ensures the read switch is activated when the strip is inserted into the instrument TOP VIEW 0 75 19mm min 4 101 6mm max to paper stop Paper Stop Alignment Mark 0 50 12 7mm min patch width 1 2 30 5mm min leader length 0 40 10 2mm min patch height ...

Страница 9: ... any time All that is required is that you insert the reflection reference into the instrument as you would with any other strip 1 Center the designated end of the reflection reference under the alignment mark 2 Insert the reference strip until it is automatically advanced by the drive motor Refer to Strip Feeding Requirement for more information 3 The LED slowly flashes green while the strip is p...

Страница 10: ... re read is required on the pass The instrument s LED will stay at solid green after all passes are successfully read Strip Positioning and Measurement Techniques The following information is provided to familiarize you with reading strips a series of printed control patches 1 Select strip type to measure from the host software 2 Position the strip so that the group of patches to measure is direct...

Страница 11: ...operly which could happen if power was removed during reprogramming Try reprogramming the instrument again refer to the programming instructions that came with your update Densitometer and software not communicating Verify that the instruments LED indicates normal operation see Instrument LED Indicator If normal close and restart the software application If this does not work reboot the computer R...

Страница 12: ...ance to achieve years of reliable operation However to protect your investment and maintain reading accuracy a few simple cleaning procedures should be performed from time to time General Cleaning Whenever required the exterior of the instrument may be wiped clean with a cloth dampened in water or mild cleaner NOTE DO NOT use any solvents to the clean the instrument this will cause damage to the c...

Страница 13: ...ference can be cleaned with a lint free cloth whenever required Make sure to return the reference to its protective case when finished Always handle the calibration reference by the edges If required a new calibration reference can be ordered from X Rite Order calibration reference part number DTP32HS 100 KIT Idler Roller s Base Surface Idler Roller s Idler Roller s Drive Wheel s Bottom Plate Surf...

Страница 14: ...ry flat spots if the instrument sits idle for and extended period of time These flat spots could cause the first few moments of a reading to contain unwanted noise To prevent this condition the instrument incorporates an automatic timer that rotates the drive wheels for 10 seconds after a 12 hour non use period A reading or computer command that occurs during a wheel rotation timer cycle will over...

Страница 15: ... 10 16 mm min in direction of travel by 0 5 13 mm min wide 1 mm wide 1 0D contrast space between patches or 0 5D min difference between patches Communication Interface Protocol as described in X Rite DTP RCI manual I O port patented bi directional RS 232 at 19 2K baud rate Communication Protocol X Rite DTP series RCI commands Data format transmitted in Density Dot Dot or Reflectance Output has x10...

Страница 16: ...rs Laboratories UL 61010 1 Canadian Standards Association CSA 22 2 No 1010 1 92 CENELEC IEC EN 61010 1 Design and specifications subject to change without notice Standard Accessories Calibration Reference DTP Series CD Serial Communication Cable integrated with the instrument 12VDC Switching Power Supply Line Cord North America Line Cord Europe Optional Accessories Mac Serial Adapter P N SE108 DB9...

Страница 17: ...trip guide Insert strip at X The DTP32R has a strip guide mechanism that ranged numerically from 5 to 30 Some software packages indicate a setting for this guide These prompts can be ignored with the DTP32HS as no guide is required Using the keyboard Push Key X The DTP32R has four keys to control the menus found on the LCD The DTP32HS does not require unique key sequences because it is software dr...

Страница 18: ...same as any normal scan Once the unit has recognized the initial barcode as being part of a set up barcode the LEDs will slowly flash between amber and green This same flash pattern will continue while scanning continuation barcodes Upon completion of the entire set up barcode the LEDs will come on steady green indicating a successful completion REFER TO THE FOLLOWING PAGES FOR X RITE SET UP BARCO...

Страница 19: ...Baud Rate Configuration First scan this bar code and then scan 1200 2400 4800 9600 or 19200 baud rate codes on the following five pages for the desired setting ...

Страница 20: ...Baud Rate 1200 ...

Страница 21: ...Baud Rate 2400 ...

Страница 22: ...Baud Rate 4800 ...

Страница 23: ...Baud Rate 9600 ...

Страница 24: ...Baud Rate 19200 ...

Страница 25: ...Auto Transmit Configuration First scan this bar code and then scan the On or Off code on the following two pages for the desired setting ...

Страница 26: ...Auto Transmit On ...

Страница 27: ...Auto Transmit Off ...

Страница 28: ...Decimal Point Configuration First scan this bar code and then scan the On or Off code on the following two pages for the desired setting ...

Страница 29: ...Decimal Point On ...

Страница 30: ...Decimal Point Off ...

Страница 31: ...Times Ten Configuration First scan this bar code and then scan the On or Off code on the following two pages for the desired setting ...

Страница 32: ...Times Ten On ...

Страница 33: ...Times Ten Off ...

Страница 34: ...Data After Pass Configuration First scan this bar code and then scan the On or Off code on the following two pages for the desired setting ...

Страница 35: ...Data After Pass On ...

Страница 36: ...Data After Pass Off ...

Страница 37: ...Delimiter Configuration First scan this bar code and then scan the Carriage Return or Carriage Return and Line Feed code on the following two pages for the desired setting ...

Страница 38: ...Delimiter CR ...

Страница 39: ...Delimiter CR LF ...

Страница 40: ...Separator Configuration First scan this bar code and then scan the Space Comma Tab Carriage Return or Carriage Return and Line Feed code on the following five pages for the desired setting ...

Страница 41: ...Separator Space ...

Страница 42: ...Separator Comma ...

Страница 43: ...Separator Tab ...

Страница 44: ...Separator CR ...

Страница 45: ...Separator CR LF ...

Страница 46: ...Min Max Configuration First scan this bar code and then scan the Off Min Max or Min and Max code on the following four pages for the desired setting ...

Страница 47: ...Min Max Off ...

Страница 48: ...Min Max Min ...

Страница 49: ...Min Max Max ...

Страница 50: ...Min Max Min Max ...

Страница 51: ......

Страница 52: ...ong Tel 852 2 568 6283 Fax 852 2 885 8610 X Rite Ltd The Acumen Centre First Avenue Poynton Cheshire England Tel 44 0 1625 871100 Fax 44 0 1625 871444 X Rite Méditerranée Parc du moulin de Massy 35 rue du Saule Trapu 91300 Massy France Tel 33 1 69 53 66 20 FAX 33 1 69 53 00 52 X Rite Italy Srl Via per Caronno 35 21040 Origgio Va Italy Tel 0039 02 96734266 Fax 0039 02 96730681 X Rite Asia Pacific L...

Отзывы: