SAFETY INSTRUCTIONS

XPOWER LIMITED WARRANTY (USA)

1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug

     the unit with wet hands or while standing in water.

2. To avoid risk of injury, do not direct air flow at face or body.

3. WARING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use Unit With Any Solid-State 

    Speed Control Device.

4. Use only with GFCI protected receptacles. Please contact a qualified electrician for 

     verification and / or installation of a GFCI receptacle if necessary.

XPOWER’s Limited Warranty covers the unit (excludes POWER CORD) from defects in material 

and craftsmanship. The Warranty covers normal use for a term of one year from the original 

date of purchase including parts, labor and one way shipping. Non-contiguous states must pay 

for roundtrip freight. A purchase receipt must be provided.

 

Important!

This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse, 

disassembly, alteration, corrosive chemicals, improper voltage, fire, flood, negligence, 

accident, improperly or incorrectly performed maintenance or repair, or failure to perform 

necessary maintenance or repair, or if the use of this product is not in compliance with the 

instructions and specifications for its use

In order to receive service or replacement parts under warranty, you must:

   1) Contact us before the warranty has expired,

   2) Call for return merchandise authorization number,

   3) Provide original, legible proof of purchase, and

   4) Ship to:

 

XPOWER Manufacture, Inc

 

220 Clary Ave.

 

San Gabriel, CA 91776

Model

X-41ATR

Voltage/Frequency

11

5

V

/60H

Z

Air

ow

3,600

 

C

F

M

AMPS

3.2A

Power

1

/3

 

H

P

Weight

24.2

 LBS

Dimensions (L x W x H)

21.9” x 9.8”

 x 

22.5”

Cord

20

 

ft.

 

/

 14AW

G

Housing

In

j

ec

ti

on-

m

olded ABS

Posi

ti

ons

360

° Rota

ti

onal 

C

overa

g

e

Timer 

Yes 

 

3

 

H

ours

Outlet

Yes 

 

2

 Outlets

SPECIFICATIONS

Содержание X-41ATR TURBO-PRO

Страница 1: ...X 41ATR TURBO PRO Professional Axial Fan OWNER S MANUAL ...

Страница 2: ...Introduction 2 Features 2 3 Operation 4 Specifications 5 Safety Instructions 5 6 Warranty 7 Troubleshooting 8 Parts List 9 Warranty Registration Form 10 INDEX ...

Страница 3: ...ompletely speed controllable a first in the industry We also offer a high quality dual outlet for Daisy Chaining and a 3 hour timer for ease of use in professional applications Enjoy EXTERNAL ROTOR MOTOR The external movement of the rotor cools down the motor more efficiently providing safer operation and longer life for the machine This ultra unique design also provides excellent power compact size a...

Страница 4: ...o turn them off SPECIALLY DESIGNED AIR FIN GUIDE Contoured to provide maximum focused and extended airflow volume and velocity 360 ROTATION RACK STAND INCLUDED Full Rotation of the axial fan to fit the need of any project from drying flooded floors painted walls and damp damaged ceilings SUPER LIGHTWEIGHT 24 2 Lbs Unit Weight Durable ABS Housing COMPACT DESIGN W STACKABILITY L 21 9 x W 9 8 x H 22 5 Uni...

Страница 5: ...aisy Chain feature only use devices under 4 AMPS for 12 AMP circuit X 41ATR axial fan has an on board Circuit Breaker If the Auxiliary Outlet overloads the Circuit Breaker will trip If the Breaker does trip unplug the units and press the Circuit Breaker Reset button Plug the units back into the power source and turn on the switch Timer Models using a timer can be set up to 3 hours long After the t...

Страница 6: ...ck Do Not Use Unit With Any Solid State Speed Control Device 4 Use only with GFCI protected receptacles Please contact a qualified electrician for verification and or installation of a GFCI receptacle if necessary Model X 41ATR Voltage Frequency 115V 60HZ Airflow 3 600 CFM AMPS 3 2A Power 1 3 HP Weight 24 2 LBS Dimensions L x W x H 21 9 x 9 8 x 22 5 Cord 20 ft 14AWG Housing Injection molded ABS Posit...

Страница 7: ...mover while unit is operating 10 All air movers in operation must be supervised at all times 11 Keep air intakes and exhausts clean at all times to avoid clogging or blocking in order to prevent overheating the unit Blocking the air intake could result in a fire or electrical hazards 12 To prevent injury to persons and to avoid objects from coming in contact with the fan blade do not remove any scr...

Страница 8: ...tly or indirectly to misuse abuse disassembly alteration corrosive chemicals improper voltage fire flood negligence accident improperly or incorrectly performed maintenance or repair or failure to perform necessary maintenance or repair or if the use of this product is not in compliance with the instructions and specifications for its use In order to receive service or replacement parts under warrant...

Страница 9: ... failure Check outlet Change to another outlet Wiring failure Contact XPOWER for repair Obstructions at the intake or exhaust of fan Remove obstruction s Fan broken Contact XPOWER for repair Weak Air Flow Obstructed vents inlets Clean out vents inlets Motor Not Running Scraping Noise From Fan TROUBLESHOOTING ...

Страница 10: ...Item No Parts Name 1 Front air cover 2 Front end cover 3 Housing 4 Outlet cover 5 AC receptacle 6 Circuit breaker 7 Handle cover 8 Power cord 9 Timer knob 10 Speed control knob 11 Switch plate 12 Timer 13 Switch 14 Side cover 15 Rack handle 16 Rack 17 Motor 18 Capacitor 19 Rear air cover 20 Rear end cover 21 Cover ...

Страница 11: ...duct warranty For multiple units please list serial numbers on a separate sheet of paper Address XPOWER MANUFACTURE INC 220 Clary Avenue San Gabriel CA 91776 USA Tel 626 285 3301 Fax 626 285 3302 Company Name Contact Person Title State Province Zip Country ...

Страница 12: ......

Страница 13: ...w noise Our Axial fans are completely speed controllable a first in the industry We also offer a high quality dual outlet for Daisy Chaining and a 3 hour timer for ease of use in professional applications Enjoy EXTERNAL ROTOR MOTOR The external movement of the rotor cools down the motor more efficiently providing safer operation and longer life for the machine This ultra unique design also provides ex...

Страница 14: ...man 3 hour timer allows you to setup multiple fans without having to comeback to turn them off SPECIALLY DESIGNED AIR FIN GUIDE Contoured to provide maximum focused and extended airflow volume and velocity 360 ROTATION RACK STAND INCLUDED Full Rotation of the axial fan to fit the need of any project from drying flooded floors painted walls and damp damaged ceilings SUPER LIGHTWEIGHT 24 2 Lbs Unit Weigh...

Страница 15: ...ty for examination and or repair 6 It s automatically operated device To reduce the risk of injury disconnect from power supply before servicing 7 Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over 8 Do not allow children to play with o...

Страница 16: ...reight A purchase receipt must be provided Important This warranty does not cover or apply to defects due directly or indirectly to misuse abuse disassembly alteration corrosive chemicals improper voltage fire flood negligence accident improperly or incorrectly performed maintenance or repair or failure to perform necessary maintenance or repair or if the use of this product is not in compliance wit...

Страница 17: ...Contact Person Title State Province Zip Country SYMPTOM PROBABLE CAUSE ACTION Switched Off Make sure unit is plugged in and switch is turned to ON mode Power failure Check outlet Change to another outlet Wiring failure Contact XPOWER for repair Obstructions at the intake or exhaust of fan Remove obstruction s Fan broken Contact XPOWER for repair Weak Air Flow Obstructed vents inlets Clean out vents...

Страница 18: ...Item No Parts Name 1 Front air cover 2 Front end cover 3 Housing 4 Outlet cover 5 AC receptacle 6 Circuit breaker 7 Handle cover 8 Power cord 9 Timer knob 10 Speed control knob 11 Switch plate 12 Timer 13 Switch 14 Side cover 15 Rack handle 16 Rack 17 Motor 18 Capacitor 19 Rear air cover 20 Rear end cover 21 Cover ...