1. While unit is unplugged and cool, unscrew nozzle a very front of unit(fig.1) and
clean out unobstructed.
2. Empty all fog fluid from the machine and replace with cleaning solution in the
tank. Plug unit in and to warm as usual.
3. Run unit in a well ventilated area unit tank is empty.
4. Replace nozzle.
5. Cleaning us now complete. Unplug and refill with a quality water based fog fluid
once cool.
All fog machine are prone to clogging due to the consistency of fog fluid and the
high temperatures at which it vaporizes. However a well maintained machine should
provide years of reliable use.
The body of the unit may be cleaned with a dry cloth. Store dry.
Maintenance & servicing
Do not allow fog fluid to become contam inated. Always replace cap after use.
Work on internal parts should be carried out by a qualified technician. Removal of
any covers is considered a breach of warranty and will not be covered under any
such agreement unless authorized first by company.
Troubleshooting
If you experience low output, pump noise or no output at all, unplug immediately.
Check fluid level, the external fuse, remote connection and main power supply, if all
appear to be ok, plug the unit in again. If fog does not come out after holding the
remote control button for 30 seconds, check the hose attached to the tank to make
sure there is fluid going through the hose. If you are unable to determine the cause
of the problem. Do not simply continue to push the remote control button as this
may damage the unit. contact us for servicing.
7. Beware of consideration around the nozzle. Consider carefully when mounting.
Caution :
1. Do not obstruct the nozzle. Fog output is
of the nozzle during operation. Never aim the nozzle directly at people or naked
flames.
2. Danger of burns. Keep out of reach of children. Do not leave machine
unattended.
3. Output nozzle becomes very hot during operation(300 degree).keep flammable
materials at least 50cm(20
”
away from the nozzle.
).
4. Always allow the fogger to cool down before cleaning or servicing.
5. Never use any other type of liquid other than water based quality fog fluid.
6. Never drink fog liquid. If its ingested, call a doctor immediately. If fog fluid
comes into contact with skin or ey es, rinse thoroughly with water.
9. No user serviceable parts inside,please refer to us for service.
8. All fog machines may splutter small amounts of fog occasionally during operation
and for a minute or so after being turned off.
1: SCREW 2:TELECONTROL 3:SWITCH 4:POWER INPUT
Introduction
Congratulations on the purchase of your new fog machine. We are confident you will
enjoy many trouble free hours with this unit. To assist with the care and use of the
product we have prepared this short guide.
Operation
This fog machine has been designed to function on a mains power supply of either 120V~60Hz or
230V~50Hz and has been fitted with a suit able power plug for use with your local
voltage. Check the label on the unit and the power plug for the correct voltage.
Place the machine on a level surface and loosen the cap of the fluid tank to fill with
quality water based fog fluid. We recommend use of pointed fog fluid as it has been
specially formulated for use with our foggers . Plug the remote control unit into the
socket at the rear and switch on to allow time to preheat. Once the machine has
reached temperature is ready to operate the green light on the remote control will
illuminate. Push the button on the remote control when lit and hold for prolong
bursts of fog.
Always monitor fog fluid level as runnin g the machine with no fluid could cause
permanent damage. please do not touch or place anything in close proximity to the
nozzle during operation or preheat as there is danger of burns.
It is normal for your fogger to have a recy cling period after long bursts when the unit
will shut itself down for a short period in order to heat up to temperature. During
this time no fog can be produced. The gr een light on the remote will illuminate when
the unit is ready for action again.
Due to the high operating temperature of fog machines it is advised that the effect
be used in well ventilated areas taking care not to obstruct the air vents. After
use,allow time to cool for safety before moving touching.
Installation /Mounting
The fogger must used in horizontal position sitting level surface or it may be
mounted using the bracket provided. Ensuring that the fog is not shooting directly at
anyone face .
Whatever method of installation you choose ,the fogger must not have more than a
15 degree angle of inclination. We always suggest that safety purpose use of a
suitable hanging clamp and safety cable is essential. We offer a range of items,
which are ideal for safe mounting.
Cleaning
Cleaning your fog machine regularly will help reduce costly parts replacement and
repair charges.
After every 40 hours of continuous operat ion or when the mach ine will be idle for a
long time it is recommend to run a cl eaning solution composed of 80%distilled
water and 20% white vinegar through the system to prevent the accumulation of
particles in the heating element.
Before connecting this unit to the mains power supply for the first time you must first
fill the fluid tank with fog fluid and check that the nozzle is clean and unobstructed.