Shooting Strategy

Shooting Strategy

Taking pictures for a flat subject

 

Taking pictures for a flat subject (2)

 

Taking pictures for a non-flat subject (1)

 

Put the contact ring on the objective lens before shooting.

The barrel part of the objective lens can be removed by 

rotating it counterclockwise and vice versa for the assembling.

To keep a stable pose without the assistance of the contact 

ring and barrel, please use two fingers to uphold the objective 

lens with another finger touching the subject surface gently. 

Move the camera up and down slightly to reach the best 

working distance. Press the camera shutter halfway to focus. 

When the AF (autofocus) green frame(s) is shown on the 

camera, fully press the camera shutter to shoot. Any shaking 

or vibration should be carefully revented during shooting.

Keep rotating the barrel until it is removable from the objective 

lens.

Have the contact ring closely touched the surface of the 

subject. Slightly press X-Loupe® on the subject to reach the 

best working distance, and press the camera shutter halfway 

to focus. The AF (autofocus) green frame(s) should show up 

when the camera focuses. Fully press the camera shutter to 

shoot. Any shaking or vibration should be carefully prevented 

during shooting.

The contact ring is not essential in this scenario unless the 

surface of the subject is vulnerable and easy to be scratched.

Aim the camera at the subject. Hold the objective lens by two 

fingers. Slightly move around the camera up and down to 

reach the best working distance, while pressing the camera 

shutter halfway to focus. When the AF (autofocus) green 

frame(s) is shown on the camera, fully press the camera 

shutter to shoot. Any shaking or vibra tion should be carefully 

prevented during shooting.

Содержание G-series

Страница 1: ...English Digital Portable Microscope User s Guide...

Страница 2: ...US7 327 526 B1 US7 821 569 B2 US7 853 137 B2 Nr 20 2007 014 240 4 Nr 20 2006 001 999 5 China Patent No Japan Patent No Taiwan Patent No US Patent No Germany Patent No In the interest of continually im...

Страница 3: ...anon digital camera IXUS 800IS 950IS Enjoy photography and micro photography with one single X Loupe For more information and downloading this user guide please visit our website at http www x loupe c...

Страница 4: ...dule Power Switch Components Components Front View Upper View LCD Monitor Back View Digital Camera Exchangeable Objective lens Light Source of Objective Lens LCD Monitor Switch Button for Coaxial Ligh...

Страница 5: ...the battery charger CB 2LX into the power outlet or attach the power cord to the battery charger CB 2LXE and plug it into a power outlet The charger indicator will light on Orange charging the batter...

Страница 6: ...hereas F is shown when switching to F Functional Illumination 1 In conventional micro photography taking a good picture is so difficult that most users have to be content with pictures of less than ex...

Страница 7: ...g Tune the brightness index as desired 1 5 Check LCD monitor Switch to Quadrant Setting for Low Angled Lighting Select which quadrants to turn on Light Source Light Source 3 Turn ON low angled lightin...

Страница 8: ...ve lens with the other red dot on the module Attach the objective lens to the module Rotate the objective lens clockwise until the sound ka is heard Do not over rotate the objective lens To change the...

Страница 9: ...d be carefully revented during shooting Keep rotating the barrel until it is removable from the objective lens Have the contact ring closely touched the surface of the subject Slightly press X Loupe o...

Страница 10: ...amera 2 Focus The auto focus function of Canon camera at optical zoom factor 4X is very sensitive and clever However while using a higher zoom factor it is getting harder to focus the subject automati...

Страница 11: ...knob of the stand and taking the pictures as desired Please refer to IXUS 950IS Advanced Camera User Guide P 51and P 52 3 Continuous Shooting and Self Timer To take pictures for a living thing such a...

Страница 12: ...ject the conventional microscopy Sometimes moving X Loupe up and down a little bit can reach the best focus The AF autofocus green frame s on the LCD means good focus whereas orange means close to the...

Страница 13: ...Timer To reduce the influence of vibration during shooting please use Self Timer for better performance refer to PowerShot 110HS User Guide Page 58 5 Single shooting is the default setting In a circu...

Страница 14: ...utton the tint on the screen will change when WB new data is set Note It is useless to adjust WB while the light source is in the mode of Blue UV or using the lens filter It s another way for Manually...

Страница 15: ...roubleshooting of IXUS camera please refer to the Adva nced Camera User Guide of IXUS 2 The LED in the objective lens is not bright a Check the battery power b Disassemble the objective lens and assem...

Страница 16: ......

Страница 17: ...page 30 page 31 MEMO MEMO...

Страница 18: ...oor No 8 Wanhe St Wenshan District 116 Taipei City Taiwan R O C TEL 886 2 2230 1168 FAX 886 2 2239 2112 e mail x loupe lumos com tw http www x loupe com http www lumos com tw Digital Portable Microsco...

Отзывы: