Revision J 9/30/2014 R830000-1060
Quick Start Guide, XDSPRO Receiver
Page 7 of 11
NOTE:
Wiring pinout for the RELAY A port is the same as on the StarGuide receiver
with Westwood One Netcue Card.
The pinouts for the DB-37 connectors are:
RELAY A - DB37M
RELAY B - DB37M
Pin
Signal
Signal
Pin
Pin
Signal
Signal
Pin
1
RLY1A
RLY1B
20
1
RLY1A
RLY1B
20
2
RLY2A
RLY2B
21
2
RLY2A
RLY2B
21
3
RLY3A
RLY3B
22
3
RLY3A
RLY3B
22
4
RLY4A
RLY4B
23
4
RLY4A
RLY4B
23
5
GND
GND
24
5
GND
GND
24
6
RLY5A
RLY5B
25
6
RLY5A
RLY5B
25
7
RLY6A
RLY6B
26
7
RLY6A
RLY6B
26
8
RLY7A
RLY7B
27
8
RLY7A
RLY7B
27
9
RLY8A
RLY8B
28
9
RLY8A
RLY8B
28
10
GND
RLY9B
29
10
GND
RLY9B
29
11
RLY9A
RLY10B
30
11
RLY9A
RLY10B
30
12
RLY10A
RLY11B
31
12
RLY10A
RLY11B
31
13
RLY11A
RLY12B
32
13
RLY11A
RLY12B
32
14
RLY12A
GND
33
14
RLY12A
GND
33
15
NQ Txd
RLY13B
34
15
NC
RLY13B
34
16
RLY13A
RLY14B
35
16
RLY13A
RLY14B
35
17
RLY14A
RLY15B
36
17
RLY14A
RLY15B
36
18
RLY15A
RLY16B
37
18
RLY15A
RLY16B
37
19
RLY16A
19
RLY16A
If you or your automation vendor has developed a program that can read Westwood
One Netcues directly, you may get the Netcue serial stream from pins 15 and 10 on the
Relay A
port on your XDS receiver (see pinout above). The “NQ TxD” pin is RS-232
data with no flow control or handshaking. Baud rate is set by default to 9600 bps 8N1.
THREE CHARACTER NETCUES:
If you currently use a Netcue/Data card in your Starguide receiver, any 3-character
Netcue that Westwood One sends out can be mapped to any contact closure you wish.
Contact
our Technical Services department or contract Help Desk to help you map your existing
Netcues to the same relay pins on one of the DB-37 connectors on your new XDS
receiver.
2. VERIFY PROGRAMMING AND ACTIVATE
In the XDS system each program, not each channel, is permissioned and labeled for
station use. Therefore, instead of tuning to a channel to find a program, you will