Wiring and Connections
WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher. Read through this section in this
entirety before running or terminating the wires to ensure proper operation and to avoid damaging equipment.
IMPORTANT! Wiring Guidelines
• The use of patch panels, wall plates, cable extenders, kinks in cables, and
electrical or environmental interference will have an adverse effect on HDMI
and Ethernet transmission limiting performance. Steps should be taken to
minimize or remove these factors completely during installation for best
results.
• WyreStorm recommends using high quality HDMI cables such as
WyreStorm Express to ensure the highest content performance available.
• The type of category cable and length used can restrict the available video
resolution. While Cat5e can be used, WyreStorm recommends using Cat6
or higher to ensure the highest content performance available. See
Video
Resolutions
in the
Specifications
table before determining cable type and
length.
HDMI Wiring
WyreStorm recommends using pre-terminated HDMI cables due to the
complexity of these connector types. Using pre-terminated cables will ensure
that these connections are accurate and will not interfere with the performance
of the product.
HDBaseT Wiring
Pin 1 Pin 8
Wire colors shown follow EIA/TIA-568B standard.
Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
IR Wiring
IMPORTANT! IR TX/RX Guidelines
• WyreStorm IR ports function differently than standard IR ports. For this
reason only WyreStorm IR emitters and receivers can be used.
• WyreStorm IR emitter and receiver cables cannot be spliced as cutting
into the cables will short the shield. While an extension cable may be used,
WyreStorm assumes no responsibility for operation using an extension
cable.
• When connecting the IR TX to an IR connecting blocks or control system
with different plugs, a cable must be made following the
diagram.
• When connecting to an IR control system use the WyreStorm CAB-IR-LINK
cable. This cable compensates for differences between the WyreStorm RX
and the control systems TX connection. Visit the
product page for details.
IR TX Port Pinout
Tip:
Anode/5V
Sleeve: Cathode/IR Signal
IR RX Port Pinout
Tip:
Ring:
IR Signal
+5V DC
Sleeve: Ground (GND)
RS-232 Wiring
Most control systems and computers are DTE where pin 2 is RX, this can vary
from device to device. Refer to the documentation for the connected device
for pin functionally to ensure that the correct connections can be made.
1 2 3
Pin 1:
Pin 2:
TX (Transmit)
RX (Receive)
Pin 3: Ground (GND)
Setup and Configuration
Set Switch
Note:
Switches shown in gray can be in any position for the described setting.
RS-232 Pass-through
(default)
1 2 3
ON
HDBaseT Update
Updates to the HDBT chip
1 2 3
ON
Firmware Updates
Allows for updating the
extenders firmware
1 2 3
ON
Long Cable Mode On
Extends transmission of
HDBT up to 140m/439ft
1 2 3
ON
Long Cable Mode Off
Maintains standard HDBT
distances
1 2 3
ON
EDID Settings
EDID Copy
4K @60Hz 2ch
1080p @60Hz 2ch
1080i @60Hz 2ch
1080p @60Hz 5.1ch
1080p @60Hz 7.1ch