1.

 

Overview 

The following document contains the Application Program Interface (API) commands to control the SW-0401-HDBT switcher via 
serial and IP commands.  Read this document in its entirety before starting any communication with the product. 

1.1

 

Before You Begin 

Verify that the following items are on hand and that all documentation is reviewed before continuing. 

SW-0401-HDBT Switcher ......................................................................................................................................................................   

Control System and Control System Documentation .......................................................................................................................   

PC or Mac for Configuring Product and Telnet Communications ...................................................................................................   

Network Connection with Network Passwords ..................................................................................................................................   

Visit the Product Page on 

WyreStorm.com

 to download firmware and additional product information .................................   

2.

 

Wiring and Communication Configuration 

WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher.  Read 
through this section in this entirety before running or terminating the wires to ensure proper operation and to avoid damaging 
equipment. 

2.1

 

RS-232 Connections 

The following wiring diagrams show the pinouts for the switcher.  While not shown, connect the TX (transmit) to RX (receive) pins at 
the control system or PC side of the cable.  Most control systems and computers are configured for Digital Terminal Equipment 
(DTE) where pin 2 is RX and pin 3 is TX. This can vary from device to device, refer to the documentation for the connected device for 
pin functionally to ensure that the connect connections can be made. 

 

2.2

 

Serial Port Settings 

Baud rate: 

57600 

Data Bits: 

8bits 

Parity: 

None 

Stop Bits: 

1bit 

Flow Control:  None 

Note: 

This switcher is not controllable via Ethernet.

 

3.

 

Command Elements 

 

Command Type: ASCII 

 

Key Words are Case Sensitive 

 

prm

 = optional parameters 

 

in = Video Input (HDMI/HDBaseT) 

 

out = Video Output (HDMI/HDBaseT) 

 

aout = Audio Output 

 

Command termination requires <CR><LF> 

Example: SET AUTOCEC_D 

out

 

prm

 <CR><LF> 

Содержание SW-0401-HDBT

Страница 1: ...com North America 844 280 WYRE 9973 UK EMEA 44 0 1793 230 343 Email Support WyreStorm com 4 2 HDBaseT Switcher SW 0401 HDBT Application Programming Interface Document Revision v1 1 Document Date Marc...

Страница 2: ...al Port Settings 3 3 Command Elements 3 4 Switcher Control Configuration 4 4 1 Enable Disable API Control 4 5 Switcher Control 4 5 1 Input Selection and Switching Configuration 4 5 2 Audio Output Volu...

Страница 3: ...the installation is run and terminated prior to making connections to the switcher Read through this section in this entirety before running or terminating the wires to ensure proper operation and to...

Страница 4: ...t SET SW hdmi1 CR LF Returns SW hdmi1 CR LF prm vga dp hdmi1 hdmi2 Select Next Input SET SW_NEXT CR LF Returns prm CR LF Example Select Next Input from VGA SET SW_NEXT CR LF Returns DP CR LF prm vga d...

Страница 5: ...audioout prm on off on means mute off means unmuted 6 Display and Switcher Power Control 6 1 CEC Configuration Action API Command Reference Parameters Enable Disable CEC Functionality SET CECCMD_ONOFF...

Страница 6: ...OFF on CR LF Returns STANDBY_ONOFF on CR LF prm on off Power Display On off SET CECPWR_ONOFF prm CR LF Returns Send CEC cmd HDMI TV prm CR LF Send CEC cmd HDBT TV prm CR LF Example Power on displays S...

Страница 7: ...6 fix7 fix0 copy fix1 4K 30Hz PCM 2Ch fix2 1920x1080 60Hz PCM 2Ch fix3 1280x720 60Hz PCM 2Ch fix4 1920x1200 60Hz PCM 2Ch fix5 1280x800 60Hz PCM 2Ch fix6 1920x1080 60Hz Dolby 5 1 fix7 4K 30Hz Dolby 5 1...

Страница 8: ...o SET FORCERGB prm CR LF Returns FORCERGB prm CR LF Example Force RGB On SET FORCERGB on CR LF Returns FORCERGB on CR LF prm on off Query RGB Video Status GET FORCERGB CR LF Returns FORCERGB prm CR LF...

Страница 9: ...800 60 1366x768 60 1600x1200 60 1920x1080 60 1920x1200 60 3840x2160 30 auto prm3 0 100 Query System Status GET SYS_STATUS CR LF Returns Info based on parameters Example Query system status GET SYS_STA...

Страница 10: ...troubleshooting be required please contact WyreStorm technical support Phone UK 44 0 1793 230 343 ROW 844 280 WYRE 9973 Email Support WyreStorm com On Line Chat Accessible through website http WyreSt...

Страница 11: ...Copyright 2018 WyreStorm Technologies WyreStorm com SW 0401 HDBT API 180321 1319 11 of 12 North America 844 280 WYRE 9973 UK EMEA 44 0 1793 230 343 Email Support WyreStorm com...

Страница 12: ...aterial contained in this document consists of information that is the sole property of WyreStorm This document is intended to provide information to allow interfacing to the relevant WyreStorm equipm...

Отзывы: