Wyrestorm CON-H2-EDID Скачать руководство пользователя страница 3

Copyright © 2019 WyreStorm Technologies | 

wyrestorm.com

CON-H2-EDID Quickstart Guide | 190530

UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973) 

[email protected]

3 of 4

Setup and Configuration

EDID Dial Settings

The dial located on the front of the product is used to set the EDIDs based on the following table.

Resolution

Dial Set

EDID copy from Output

0

1024x728 @60Hz 2Ch

F

1280x1024 @60Hz 2Ch

C

1280x720p @60Hz 2Ch

4

1280x768 @60Hz 2Ch

E

1280x960 @60Hz 2Ch

D

1360x768 @60Hz 2Ch

B

1400x1050 @60Hz 2Ch

A

Resolution

Dial Set

1440x900 @60Hz 2Ch

9

1600x1200 @60Hz 2Ch

7

1600x900 @60Hz 2Ch

8

1680x1050 @60Hz 2Ch

6

1920x1080p @60Hz 2Ch

3

1920x1200 @60Hz 2Ch

5

3840x2160p @30Hz 2Ch

2

3840x2160p @60Hz 2Ch

1

Advanced Configuration

The following steps require the use of the use of the 

WyreStorm Management Suite

 v1.6 or higher. Download the latest version from the product page before 

continuing with the installation.

Initial Configuration Tool Setup

1.  Connect the converter to a PC using the RS-232 port. Refer t

RS-232 Guidelines

 for pinout.

2.  Open the WyreStorm Management Suite and select the CON-H2-xxxx Configuration Tool from the menu.
3.  Under RS-232 Port Configuration select the COM port for the PC and set the baud rate to 57600.
4.  Select the Connect button to connect the PC to the converter.

EDID Write from a File

If an EDID file is available it can be uploaded into the converter for setting the desired EDID.

1.  Under RS-232 Port Configuration select the COM port for the PC and set the baud rate to 57600.
2.  Under EDID Write select Choose File to select the file to upload.
3.  Once the selection dialog closes, select Import to upload the file to the converter.

Connected Device On/Off Triggering

Devices such as projectors or displays connected to this product can be controlled from via connection to the RS-232 port. Commands for the devices are 
entered within the CON-H2-xxxx Configuration Tool.

1.  Under Power On/Off Pre Loading set the baud rate for the device to be controlled.
2.  Select Send next to the Baud Rate to send it to the converter.
3.  Enter a command for Power On and select HEX if the command is HEX.
4.  Select Send next to Power On to send the command to the converter.
5.  Enter a command for Power Off and select HEX if the command is HEX.
6.  Select a delay time for powering Off the device after no HDMI signal is detected.
7.  Select Send next to Power Off to send the command to the converter.
8.  Select a String terminator to use for the commands and select the Set button.

Configuring Relays

The relays on the converter can be programmed to be Latch or Momentary based on the functionality of the connected device. This setting is the same for both 
relays.

1.  Under Set Relay Mode select Latch or Momentary for Relay Mode.
2.  Select the Set button to send the setting to the converter.

Отзывы: