UV Purification Systems
5
Setting Up
Important Considerations
Wyckomar purifiers are installed either at the main water supply line or at point
of use. In some installations, particularly where plumbing is old, the water may
become re-contaminated in the pipes between the purifier and the faucet. Be sure
to follow instructions under “Disinfecting Your Water System” on Page 9
Wyckomar purifiers are designed to be installed vertically and work best when
mounted in this position. However, in cases with space restrictions, the unit may
be mounted horizontally (see Installation Diagrams on Page 6).
Important: Clearance to the side or above the unit for lamp exchanges
should be equal to the length of the purifier.
The manufacturer’s warranty is only applicable when prefiltered water is used.
Prefilters (to 5 micron) remove sediment particles that can reduce the effective
-
ness of the UV lamp or potentially damage the unit.
If a water softener, iron removal system or other treatment device is installed or
planned for, your purifier should be located closest to the faucet.
Install your Wyckomar purifier indoors in a protected area. The temperature should
not fall below 4 ˚C (40 ˚F). Avoid conditions with high humidity to prevent con
-
densation on the purification chamber. Ideal temperature conditions range from
9 ˚C to 29 ˚C.
Use Teflon tape (T-tape) liberally on all pipe connections (3 turns around the fit
-
ting). Do not use any other sealants other than food grade pipe dope.
Use food-grade silicon or plumber’s grease on O-rings. DO NOT use oil-based
products.
Caution: The ballast and all electrical connections must be mounted and in-
stalled above water lines to prevent the possibility of electric shock in the case
of a water leak. A grounded electrical outlet is required (GFCI is preferred).