The compressor fails to start.

– The motor protector

 5

 is actuated.

> Disconnect power supply, and wait few minutes. 

Press the motor-protector 

 5

 and then press the 

On/Off switch

 1

 to switch on the compressor. If 

the motor protection is actuated again, contact 
the customer service. 

– The manometer

 15

 shows a pressure greater 

than 7.5 bar (for the K 210 5 bar) (cutting-in 
pressure).

> Release pressure until the pressure switch

 7

 

switches on. 

– Mains voltage fails.

> Check the electrical leads, etc.

Compressor runs uninterruptedly.

– Intake filter

 4

 is dirty.

> Clean filter or replace.

– The compressor is overloaded.

> Reduce the compressed air requirement.

– Leakage in the subsequent lead system.

> Eliminate leakage.

– Compressor is defective. (Pressure switch faulty).

> Contact the customer service.

The compressor runs for a short time when reaching the cutting-in pressure but then automatically 
switches off.

– The compressor was not de-pressurised because 

the electrical feed was interrupted during opera-
tion. 

> Switch the compressor off using the On/Off 

switch

 1

 and then switch it on again. 

– On/Off switch

 1

 is defective.

> Contact the customer service.

– The length of the mains connection lead is not 

permissible or the conducting cross-section is too 
small. 

> Lead length max. 25 m with a cross-section of  

1.5 mm

2

.

At standstill, compressed air escapes for a longer period through relief valve 6 under pressure switch 7, 
until the cutting-in pressure is reached.

– Non-return valve

 16

 has a leak or is defective.

> Contact the customer service.

During operation compressed air escapes through relief valve 6.

– Relief valve

 6

 has a leak.

> Contact customer service.

Compressor often switches on.

– Condensation water in the compressed air reser-

voir

 17

.

> Drain condensation water.

– Compressor is overloaded.

> Reduce compressed air requirement.

– Reduced performance due to worn valve plate.

> Contact customer service.

Safety valve 14 blows off.

– Reservoir pressure is greater than the opening 

pressure of the safety valve

 14

.

– Pressure switch

 7

 must be re-set or changed;  

contact customer service.

– Safety have faulty, it must be replaced. Contact 

customer service.

Error Detection

0701 221.book  Seite 16  Mittwoch, 2. Juni 2010  1:38 13

Содержание master K 210

Страница 1: ...av original driftsinstruks Alkuper isen k ytt ohjeen k nn s vers ttning av bruksanvisning i original Orijinal i letim talimat terc mesi T umaczenie oryginalnej instrukcji eksploatacji Az eredeti keze...

Страница 2: ...I F E P NL DK N FIN S GR TR 6 11 12 17 18 23 24 29 30 35 36 41 42 47 48 53 54 59 60 65 66 71 72 77 78 83 84 89 90 95 96 101 102 107 108 113 114 119 120 125 126 131 132 137 138 143 144 149 0701 221 bo...

Страница 3: ...1 7 12 6 14 16 18 19 20 17 11 13 22 21 15 4 5 2 9 10 3 8 22 0701 221 book Seite 3 Mittwoch 2 Juni 2010 1 38 13...

Страница 4: ...16 1 7 6 12 14 19 18 17 20 2 11 11 13 21 15 8 3 4 9 10 5 22 22 0701 221 book Seite 4 Mittwoch 2 Juni 2010 1 38 13...

Страница 5: ...14 15 21 11 13 12 8 17 18 6 16 19 20 2 7 1 3 9 10 5 4 0701 221 book Seite 5 Mittwoch 2 Juni 2010 1 38 13...

Страница 6: ...and plug If dam age is detected do not use the ma chine Have repairs performed only by a qualified technician Nev er open the machine yourself Compressors should only be operated and serv iced by tra...

Страница 7: ...ny lengths be yond this require 2 5 mm2 If the cross section of the conductor is too small this will cause a volt age drop and there is no guarantee that the mo tor will start correctly Cable reels mu...

Страница 8: ...ter use set the pressure reducer 21 back to 0 All Models are equipped with an additional quick coupling not reduced 12 Before connect ing more than one pneumatic tool to the com pressor please check t...

Страница 9: ...r should be carried out by a W rth MasterSERVICE agent For all correspondence and spare parts orders al ways include the article number on the type plate of the machine For the current spare parts lis...

Страница 10: ...itch the compressor off using the On Off switch 1 and then switch it on again On Off switch 1 is defective Contact the customer service The length of the mains connection lead is not permissible or th...

Страница 11: ...can be accepted only when the machine is presented undisassembled to a W rth branch office your W rth sales representative or a customer serv ice agent for W rth pessure air and power tools Measured...

Отзывы: