Start signal
Command | 0x40
Length
Status
CS
0x02
0x42
0x01 0x00
1 Byte
1 Byte
Status:
0x00:
Request received, will go to sleep now
0x01:
Operation failed
0xFF:
Operation not permitted
Please note that the
pin has a second function.
If the mod-
ule is not in
ACTION_SLEEP
mode and the UART was disabled using the
, the UART can be re-enabled by applying falling edge,
holding the line low for at least 10ms before applying a rising edge and
holding it high for at least 10ms. In this case the module answers with a
message.
7.5.4. CMD_SLEEP_IND
This indication is sent by the module when the
has expired without a
connection to the module.
Format:
Start signal
Command
Length
Status
CS
0x02
0x82
0x01 0x00
0x00
1 Byte
Status:
0x00:
Advertising timeout detected, will go to sleep now
7.5.5. CMD_FACTORYRESET_REQ
This command triggers a factory reset of the module. First, the default User Settings are
restored, then the module is reset.
Format:
Start signal
Command
Length
CS
0x02
0x1C
0x00 0x00
0x1E
Response (
Start signal
Command | 0x40
Length
Status
CS
0x02
0x5C
0x01 0x00
1 Byte
1 Byte
Status:
Order code 2608011x24010