WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-II
8.21. UART_Flags: Configure the UART
Settings
index
Designation
Permissible
values
Default value
Permissions
Number of
Bytes
27
0,1
0
read/write
1
The user setting
specifies whether the UART uses flow control or not.
Bit no.
Description
0
Set this Bit to 1 to enable the flow control pins
and
1-7
Reserved.
For baud rates faster than 230400 Baud, the flow control pins
and
are enabled.
The evaluation board Proteus-II-EV version 2.0 does not provide the connection
between the flow control pins of the module and the evaluation board’s USB
port. Thus in this version of the Proteus-II-EV the flow control can be only
used, if the on-board UART is disconnected (remove respective jumpers on
JP2) and all UART lines (
and
) are connected to an
external FTDI cable.
8.21.1. Example 1
Enable the flow control using
with settings index 27
Start signal
Command
Length
Settings index
Parameter
CS
0x02
0x11
0x02 0x00
0x1B
0x01
0x0B
Response
: Successfully modified the setting.
Start signal
Command | 0x40
Length
Status
CS
0x02
0x51
0x01 0x00
0x00
0x52
8.21.2. Example 2
Request the
using
with settings index 27:
Start signal
Command
Length
Settings index
CS
0x02
0x10
0x01 0x00
0x1B
0x08
Response
: Successfully read out the value 0x00, meaning that the flow control is
disabled.
Order code 2608011x24010
118