Start signal
Command
Length
CS
0x02
0x01
0x00 0x00
0x03
Response:
Start signal
Command
| 0x40
Length
Module
role
Module
actions
More info
CS
0x02
0x41
0x08 0x00
0x02
0x03
0x11 0x00 0x00
0xDA 0x18 0x00
0x99
The module is connected to another module with
0x11 0x00 0x00 0xDA 0x18
0x00.
7.5.2. CMD_RESET_REQ
This command triggers a software reset of the module.
Format:
Start signal
Command
Length
CS
0x02
0x00
0x00 0x00
0x02
Response (
Start signal
Command | 0x40
Length
Status
CS
0x02
0x40
0x01 0x00
1 Byte
1 Byte
Status:
0x00:
Request received, will perform reset now
0x01:
Operation failed
0xFF:
Operation not permitted
7.5.3. CMD_SLEEP_REQ
This command is used to start the system-off mode (
ACTION_SLEEP
). After entering this mod-
e, the module has to be woken up using the
pin (apply a low signal at this for
at least 5ms and release it to high again) before any other action can be performed. The
UART interface as well as the Bluetooth
®
LE interface are shut down in this mode. For more
details, see chapter
Format:
Start signal
Command
Length
CS
0x02
0x02
0x00 0x00
0x00
Response (
Proteus-III reference manual version 1.3
© August 2020
www.we-online.com/wireless-connectivity
83