![Würth WDM 3-12 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/wurth-0/wdm-3-12/wdm-3-12_user-manual_1001302030.webp)
Würth WDM3-12
13
EN
Technical Data
* applies for 100 % target reflectivity (white painted wall), low
background illumination, 25 ºC
** applies for 10 to 500 % target reflectivity, high background
illumination, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confidence
level of 95%. The maximum tolerance may deteriorate to 0.1
mm/m between 10 m to 30 m and to 0.15 mm/m for distances
above 30 m
**** applies for 100 % target reflectivity, background illumi-
nation of approximately 30'000 lux
For accurate indirect results, the use of a
tripod is recommended.
Distance measurement
Typical Measuring Tolerance*
± 1.0 mm / 0.04 in ***
Maximum Measuring Toler-
ance**
± 2.0 mm / 0.08 in ***
Typical Range*
80 m / 262 ft
Range at unfavourable condi-
tion ****
60 m / 197 ft
Smallest unit displayed
0.1 mm / 1/32 in
Ø laser point
at distances
6 / 30 / 50 mm
(10 / 50 / 80 m)
General
Laser class
2
Laser type
635 nm, < 1 mW
Protection class
IP65 (dust tight and jet
water protected)
Autom. laser switch off
after 90 s
Autom. power switch-off
after 180 s
Battery durability (2 x AAA)
up to 5000 measurements
Dimension (H x D x W)
127 x 61 x 31 mm
5 x 2.4 x 1.22 in
Weight (with batteries)
164 g / 5.27 oz
Temperature range:
- Storage
- Operation
-25 to 70 °C
-13 to 158 °F
-10 to 50 °C
14 to 122 °F
i
Functions
Distance measuring
yes
Min/Max measuring
yes
Permanent measuring
yes
Stake-out
yes
Addition/Subtraction
yes
Area
yes
Volume
yes
Pythagoras
2-point, 3-point, partial height
Memory
10 displays
Beep
yes
Illuminated display
yes
Multifunctional endpiece
yes