20
Tips for troubleshooting
Malfunction
Possible cause
Remedy
The green indication of the
charger remains dark; bat-
tery cannot be charged
The plug of the mains adapter is not completely
pluged into the socket or the connection to the
charging cradle is interrupted
Plug in mains adapter correctly; connect it correctly
to the charging cradle
Power socket defective
Have the power socket checked by a qualified
technician
The green LED or the charger / mains adapter is
defective
Have the charger / mains adapter checked by a
customer service authorized by Würth
Fan motor does not start
working after the sleeve has
been pressed against the
surface.; the charging state
indication is dark
Battery is not correctly inserted
Remove battery and insert it again until it clicks into
place
Battery contacts soiled, oily or corroded
Clean battery contacts
Battery deeply discharged or defective
Charge battery or remove (see Battery and charger
section)
Fan motor defective
Have the device checked by a customer service
authorized by Würth
The firing process was not
triggered although the
sleeve had been pushed
and the trigger had been
actuated; normal fan motor
operation; charging state
indication dark
Gas cartridge empty
Change the gas cartridge
Igniter / ignition plug defective
Have the device checked by a customer service
authorized by Würth
It is not possible to push in
the sleeve completely or
partly
Blockage due to jammed magazine, pin jammed
in ejection channel
Clear the jam (see Eliminating blockages section)
Contact arm of sleeve twisted or defect
Have the device checked by a customer service
authorized by Würth
Magazine strip is not moved
forward
Use of wrong pins / magazine strips
Only use genuine Würth pins
Magazine strip / follower is stiff
Clean magazine
Firing performance reduces
significantly or is insufficient;
pins are not driven in
completely
Combustion chamber insufficiently filled or gas
cartridge almost empty
Check gas cartridge for correct seating or replace
gas cartridge
Overheating due to insufficient cooling or
air supply
Do not hold your hand in front of the cover or clean
filter pad
Combustion chamber not compressed correctly:
Test: Press sleeve against the surface for approx. 1
min, then actuate the trigger.
If no pin is fired, there is a loss in compression.
Have the device checked by a customer service
authorized by Würth
Sleeve does not return to
initial position
Worn or twisted driver's blade; piston jammed due
to defective piston rings; contact arm of sleeve
twisted
Have the device checked by a customer service
authorized by Würth
Exhaust openings soiled or clogged
Clean the exhaust gas openings
Unbalanced operation of
device, interrupted fan motor
operation
Intern electric disconnection or loose contact
Have the device checked by a customer service
authorized by Würth