24
Messages
Information messages
▸
In the event of an accident, an error code is displayed in the 7-segment display.
▸
Pressing the Electrode/TIG button causes the information message to be deleted.
Note
The machine remains functional with limitations after the information message appears; the fault
must be remedied as quickly as possible.
Fault
Cause
Possible remedy
H06
EEProm
Read/write error
Communication fault with EEProm
Switch machine off and on again, or carry out master
reset
Error Messages
▸
If a fault occurs, an error code is displayed in the 7-segment display
[9]
. By pressing the menu button
[8]
the sub-error (sub-code) is displayed.
Note
Welding is not possible as long as an error code is displayed.
Code
Fault
Possible cause
Remedy
E01
Overheating
Admissible cyclic duration factor
exceeded
Leave the machine switched on and allow to cool
Fan defective
Check fan: Switch machine off and on again, fan must
come on briefly
E02
Power pack
Power pack controller fault
Contact Service
E03
Current sensor
Current sensor faulty
Contact Service
E06
Primary current trans-
former
Current difference between current trans
-
former and current sensor too high
Contact Service
E07
Supply voltage 15 V
Internal power supply fault
Contact Service
E13
Operating panel iden-
tification
Panel identification defective
Contact Service
E14
Operating panel
Operating panel module detective
Contact Service