WURM FRIGOLINK ANI-1F1 Скачать руководство пользователя страница 3

ANI-1F1

ANI-1F1_V2.1.4_PI_2018-06_EN.fm

3

Subject to technical changes

FRIGOLINK

1.2 Safety instructions

Writing conventions

Vorsicht!

CAUTION!

Avoid the described hazard: Otherwise 

minor

 or 

medium

 bodily injury or property damage will

result.

 Warnung!

WARNING!

Avoid the described hazard: Otherwise there is danger from 

electric voltage

 that can lead to

death or 

serious

 bodily injury.

For your safety

For safe operation and to avoid personal injury and equipment damage through operating error, al-
ways read these instructions, become familiar with the device, and follow all safety instructions on the
product and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische
Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device
if the product is sold. Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in case of
improper use or use for other than the intended purpose.

 Warnung!

WARNING! DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!

Switch off the power to the entire plant when installing, wiring or removing! Otherwise a mains
voltage and/or external voltage may still be present even if the control voltage is switched off!

The wiring of the device should be carried out only by a qualified electrician!

Use only the correct tools for all work!

Check all wiring after connection!

Take note of the maximum loads on all connections!

Never expose the device to moisture, for example due to condensation or cleaning agents!

Take the device out of operation if it is faulty or damaged and is therefore compromising safe
operation!

Do not open the device!

Do not repair the device yourself! If required, send it in for repair with an exact description of the
fault!

Vorsicht!

CAUTION! ELECTROMAGNETIC INTERFERENCE CAN CAUSE FAULTS!

Use only shielded data lines and place them far away from power lines!

Target group

This manual is intended for "service technician" personnel.

Intended use

The ANI-1F1 is a process control module for CO

2

 refrigeration plants 

with compound and gas cooler control

Содержание FRIGOLINK ANI-1F1

Страница 1: ...gas temperature Oscillation protection function Blocking time after compressor fault Two step load shedding and fast return flow Operating hours counter for each compressor Low temperature compressor...

Страница 2: ...rcuit diagram 5 Digital inputs DI 1 DI 20 5 Analogue inputs Uin 1 2 6 Analogue inputs Iin 1 Iin 5 6 Analogue inputs S 1 S 16 7 1 3 2 Output circuit diagram 8 Digital outputs relays K 1 K 14 8 Digital...

Страница 3: ...intended purpose Warnung WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND OR FIRE Switch off the power to the entire plant when installing wiring or removing Otherwise a mains voltage and or external v...

Страница 4: ...58 160 151 153 155 157 159 Relay K 3 14 Relay K1 K2 Solid State Relay V 1 4 0 10V Analog Output Uout 1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130...

Страница 5: ...1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 230V N 10 1 neutral terminal...

Страница 6: ...ult PSL LP com pound 136 N 127 DI 17 230V Fault HP compound 137 N 128 DI 18 230V Fault in GC fan 1 138 N 129 DI 19 230V UPS fault 139 N 130 DI 20 230V Fault RC protection 140 N Terminal Analogue input...

Страница 7: ...S 3 DGF Pressure gas temper ature LT compressor desuperheating 167 168 S 4 TRK External temperature 169 170 S 5 DGF Temperature gas cooler outlet T GK 1 171 172 S 6 DGF Temperature gas cooler outlet T...

Страница 8: ...Output Uout 1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 230V N 10 1 neut...

Страница 9: ...output SSR Contact arrange ment Assignment 231 Semiconductor V 1 4 60VA 230V NO MT HG bypass valve suction gas monitor ing 232 COM 233 Semiconductor V 2 4 60VA 230V NO Post injection MT 234 COM 235 Se...

Страница 10: ...each 4 2 A 230V 211 201 210 K 1 4 each 4 2 A 230V 220 K 10 14 each 4 2 A 230V 221 230 S16 194 S 15 11 Sensor 190 191 181 S 10 6 Sensor 180 171 170 S 5 1 Sensor 161 Iin 1 5 4 20mA 160 151 Uin 2 1 0 10...

Страница 11: ...tage is switched off Top hat rail installation 1 There are 2 fastening catches located on the back of the module A Press both catches a downward until they engage with a click 2 There are 4 retaining...

Страница 12: ...ting voltage green fault red 4 x LED green CAN bus data traffic CAN Tx CAN Rx Sensors 16 x DGF TRK Communication C BUS 3 wire CAN bus interface shielded galvanically isolated screw terminals 2 5mm2 an...