Page | 17
Tower Tubing Assembly. Change out the Tower Tubing Assembly. See
Appendix H: Disassembling the Tower
for
instructions on how to replace the Tower Tubing Assembly.
Symptom 9: Liquid Leaks Inside Refrigerated Space/Rear Enclosure
1.
If leak is from a barbed joint:
a.
Verify that the Oetiker clamp is completely closed by viewing the gap size at the clamp actuator. If a gap
exists, use Oetiker pliers to tighten clamp.
See
Appendix A: Oetiker Clamp Application
for reference.
b.
If Oetiker Clamp is incorrectly installed or incorrect Oetiker Clamp is installed, cut off the barbed fitting and
replace it with a new barbed fitting with the appropriate Oetiker Clamp. If the length of the tube is too
short, then replace the entire length of the tubing cut to match the original tubing length.
See
Appendix A:
Oetiker Clamp Application
for reference.
c.
Connect a keg filled with water and pressurize system to verify the leak has stopped.
2.
If leak is from a push to connect fitting:
a.
Push the tube/stem further into the push to fit fitting.
b.
If the tubing/stem pushes in further, then connect a keg filled with water and pressurize system to verify
the leak has stopped.
c.
If fitting is leaking still, replace the fitting. See
Appendix D: John Guest Speed Fit Guide
for reference.
3.
If leak is from filter, open the filter cap and verify all sealing O-Rings are installed. There should be one O-Ring on
the filter cap and one O-Ring on the filter screen. If either O-Ring is missing, replace it before reinstalling the
Filter Screen back into the unit.
See Figure 32.
4.
If leak is coming from Flowmeter-Solenoid Module (product line), replace the entire module Refer to
Appendix
G: Flowmeter Solenoid Module Replacement
for procedure.
Symptom 10: Tower Leaks
1.
If leak is from locknut on the faucet (
See Figure 33
), tighten the locknut and verify the leak has stopped. If leak
does not stop then check for O-Ring:
Filter Screen
O-Ring
Filter Cap
O-Ring
Figure 32: Filter O-Rings.
Содержание JoeTap NITCOM
Страница 1: ...Page 1 JT TFN20M07 110 JoeTap NITCOM Repair Manual 110V JoeTap NITCOM Repair Manual 110V Rev C ...
Страница 55: ...Page 55 Appendix C JoeTap NITCOM 110V Wiring Diagram ...
Страница 56: ...Page 56 Appendix D John Guest Speed Fit Guide ...
Страница 79: ...Page 79 Appendix J Fridge Functionality Maintenance and Troubleshooting Guide ...
Страница 80: ...Page 80 ...
Страница 81: ...Page 81 Refrigeration System Wiring Diagram ...