2

The indictor A is red when power is on
The indictor A is red and flashing when receiving the wireless signal
The indictor A is green and flashing when in code pairing mode
The indictor B is green when calling for heat
The indictor B is red when set to external limitation protection
The indictor B red flashing shows a sensor error
The indictor B green flashing shows entering the external limitation value select

Press the button for 8 seconds untill the indictor B flashes green,the receiver is now in 
external probe limitation setting mode.
Press the button softly to cycle between the following four states.
Indicator A - green shows external limited at 30

o

C

Indicator A - red shows external limited at 40

o

C

Indicator A - yellow shows external limited in 55

o

C

Indicator A - without light shows no external limitation set.

The receiver will save current setting automatically when nothing is pressed for 8 seconds and will 

quit the limitation setting mode.

Green    

  Calling for heat

Red  

 

  Limitation protective

Red flashing     Sensor ERR
Green flashing     Selected the limitation value

Green flashing     Entering limitation value selected

Red 

  Power

Red Flashing   

Receiving Signal

Green Flashing  

Code Pairing State

Green    

 

external limited at 30°C

Red  

 

 

external limited at 40°C

Yellow   

 

external limited at 55°C

None    

 

external limited closed

Description of work state

Limitation value select (for external probe (if used))

Indicator A

Indicator A

Indicator B

Indicator B

Button

Press for 

8 sec