User Manual

 

 

 

Auto/manual mode switch 

When there is no menu on the screen, keep button 

  depressed to switch between 

the manual mode and automatic mode. 

AutoSpan   

ManualSpan

 

 

 

 
 

Enter PIC mode   

When there is no menu on the screen, press button 

 to enter PIC mode, the 

following info will be displayed on the screen 

 

Visual Spot 

 

Fusion 

 

 

 

 

Spot analysis 

In the PIC mode, press button 

  to enter spot analysis mode 

 

 

 

Left/Right

 

 

Up/Down

 

 

 

-

 Press button 

  to switch between the X or Y coordinate of the spot 

-

 Press button 

 or button 

  to adjust the value of X or Y’s coordinate. 

-

 Press button T to exit the spot analysis and return to the real-time IR mode 

 

Infra Fusion   

In the PIC mode, press button 

  to enter visual /InfraFusion mode

   

-

 In the InfraFusion mode, press button 

 or button 

  to adjust the proportion 

of fusion 

-

 In the InfraFusion mode, press button T to return to the real-time IR mode. The 

proportion will be saved as the default value when start up the fusion mode next time. 

 
 

Laser On/Off   

11 

 

Содержание EasIR-1

Страница 1: ...uhan Guide Infrared Co Ltd No 26 Shucheng Rd Hongshan District Wuhan 430070 P R China Telephone 86 27 8767 1991 Facsimile 86 27 8767 1927 Email overseas guide infrared com Internet www guide infared c...

Страница 2: ...relating to electromagnetic compatibility and safety EMC directive 89 336 EEC Low voltage directive 73 23 EEC Copyright Wuhan Guide Infrared Co Ltd 2009 All rights reserved worldwide No parts of the p...

Страница 3: ...tions 1 Maintenance 2 Calibration and Repair Philosophy 2 Technical Support 3 Feedback to Us 3 System Overview 3 System Configuration 3 Technical Specification 4 System Features 6 Parts Described 8 Ch...

Страница 4: ...ASIRTM 1 Thermal Camera at very high intensity radiation sources such as the sun carbon dioxide lasers or arc welders etc Do not expose the EASIRTM 4 EASIRTM 2 EASIRTM 1 Thermal Camera to dust and moi...

Страница 5: ...h a soft cloth dampened with water and a mild detergent Optical surfaces The lens of an IR camera is very expensive Replacement or repair may be thousands of dollars The anti reflective coating on the...

Страница 6: ...on the cover of this User Manual or by email to the following address overseas guide infrared com System Overview EASIRTM 4 EASIRTM 2 EASIRTM 1 is a new infrared camera of Guide infrared breaks the IR...

Страница 7: ...0 pixels 25 m Spectral Range 8 14 m Thermal Sensitivity 100mk at 30 Field of View Focus 20 6 X 15 5 11mm Palette 8 6 4 Focus Automatic or motorized thermal visual Motorized thermal Motorized thermal V...

Страница 8: ...ation Class 2 semiconductor laser N A Power System Battery Type AA rechargeable battery field replaceable AA Alkaline battery also usable Charging System In camera or in battery charger Battery Operat...

Страница 9: ...owerful analysis software support image information read in powerful further analysis live trend analysis multipage generation by over 9 IR images real time video recording report generation analyzes...

Страница 10: ...2 to protect optics 3 for outdoor inspections USB 2 0 Realtime image video data transfer to PC and real time control of the camera on PC realizes video transfer and operation control User can record o...

Страница 11: ...User Manual Parts Described 1 LCD Display 2 Charging Indicator 3 Function Softkeys 4 Microphone 5 Battery Cover 6 Speaker 7 Visual Camera 8 Laser 9 IR Lens 8...

Страница 12: ...indicator will be constant red for both powering on and off y Do not use the adapter when there are non rechargeable batteries in the battery compartment How to use the batteries y Insert the batterie...

Страница 13: ...ies together to operate the camera y Do not mix batteries of different types together to operate the camera y AA Alkaline batteries are not chargeable y Please take out all the batteries when the came...

Страница 14: ...nalysis mode Left Right Up Down Press button to switch between the X or Y coordinate of the spot Press button or button to adjust the value of X or Y s coordinate Press button T to exit the spot analy...

Страница 15: ...s no menu on the screen press button T to freeze the image the following info will be displayed on the screen Save Voice Visual IR y Press button T again to exit frozen mode and return to the real tim...

Страница 16: ...ode press button to enter sub menu parameter setting Emiss Tamb Distance Palette RelHum Laser OK y In the sub menu Parameter press button to confirm the highlighted option and enter the next sub menu...

Страница 17: ...e To automatically focus y Aim the lens at the target y Press to activate the menu y Make sure the target is in the middle of the LCD and then press the softkey labeled Auto until the image on the LCD...

Страница 18: ...anual mode and to adjust Tmin and Tmax manually Tmin Tmax y Press button to increase the Tmax value press button to decrease the value press button to switch between Tmin and Tmax adjustment mode y Pr...

Страница 19: ...notation can only be added before saving an image When freeze an image the Image Capture menu appears To add a voice annotation to the image y Press the softkey labeled Voice y Press the softkey label...

Страница 20: ...r setting then choose Tamb and select Set option to set the value manually by pressing button and button The new measurement will be based on the saved tamb value until re enter Tamb option and exit w...

Страница 21: ...USB2 0 for further analysis by Guide IR software The Infrared video function is displayed in the computer and controlled by the Guide IR Analyser Before the communication please install the USB drive...

Страница 22: ...ox as following Select and press ok to confirm the infrared video is open as following z Open Film Use this command to open the saved Video file in the directory path of PC The software will play this...

Страница 23: ...ry when opening infrared video and perform the track circle Menu Bar Menu bar consists of seven sub menu options including File Video Measure Tools View Window and Help Keeping left button of the mous...

Страница 24: ...ightness of each image file This command utilizes this mapping function to adjust brightness of the current opening image file Dialog box of Temp Range will appear after choosing this command Moving t...

Страница 25: ...aying video Record command Use this command or press to record the video capture and save it in appointed directory The default saving directory is in the sub directory of capture under installation d...

Страница 26: ...camera you have to install the camera USB Driver to PC and use the Guide IrAnalyser software to transfer images to PC Install USB driver to PC When there is no menu in the live thermal image properly...

Страница 27: ...User Manual y Installation starts When getting to the step as shown below choose Continue anyway to proceed further y Installation continues and finishes quickly Click button Finish 24...

Страница 28: ...Controller it indicates the driver has been properly installed and you can transfer data from the camera to PC now y The procedures to go to Device Manager is as follows Clicking My Computer Clicking...

Страница 29: ...User Manual 26...

Отзывы: