wtw IQ SENSOR NET MIQ/A Скачать руководство пользователя страница 13

MIQ/A

Technical data

13

ba75775e01

08/2008

5

Technical data

Note

General technical data on MIQ modules are given in the T

ECHNICAL

 

DATA

 chapter of the IQ S

ENSOR

N

ET

 system operating manual.

Electrical data

 

Instrument safety

Terminal connections

Nominal voltage

Max. 24
VDC via the IQ S

ENSOR

N

ET

 (for details, see 

chapter T

ECHNICAL

 

DATA

 of the 

IQ S

ENSOR

N

ET

 system operating manual).

Power consumption

Approx. 1,5 W

Protective class

III

Number of MIQ/A in a 
IQ S

ENSOR

N

ET

 system

1

Applicable norms

– EN  61010-1

– UL 3111-1

– CAN/CSA C22.2 No. 1010.1

IQ S

ENSOR

N

ET

 

connections

2
2 additional SENSORNET terminators that 
can be activated (terminating resistors)

Terminal type

Screw-type terminal strip, accessible by 
opening the lid

Terminal ranges

Solid wires:

Flexible wires:

0.2 ... 4.0 mm

2

AWG 24 ... 12
0.2 ... 2.5 mm

2

Cable feeds

4 cable glands M16 x 1.5 on the underside 
of the module

Содержание IQ SENSOR NET MIQ/A

Страница 1: ...ba75775e01 08 2008 IQ SENSOR NET MIQ A Operating manual Fully automatic air pressure compensation in the IQ SENSOR NET system 2020 XT USB Power OK...

Страница 2: ...tween this operating manual and your instrument Also we cannot guarantee that there are absolutely no errors in this manual Therefore we are sure you will understand that we cannot accept any legal cl...

Страница 3: ...1 5 1 2 Features of the MIQ A 1 6 2 Safety instructions 2 7 2 1 Authorized use 2 7 2 2 General safety instructions 2 8 3 Installation 3 9 3 1 Scope of delivery 3 9 3 2 Installation in the IQ SENSOR NE...

Страница 4: ...Contents MIQ A 4 ba75775e01 08 2008...

Страница 5: ...has a modular structure like the IQ SENSOR NET system itself It consists of a system operating manual and the operating manuals of all the components used Please file this component operating manual...

Страница 6: ...ly automatic air pressure compensation for D O sensors see system operating manual With the standard MIQ module housing the MIQ A has the same characteristics as all MIQ modules regarding stability le...

Страница 7: ...in the vicinity of the IQ SENSOR NET system Directions The following symbols indicate special features in the individual chapters of this operating manual Note indicates notes that draw your attentio...

Страница 8: ...l safety instructions in this operating manual are followed during its use The failure free function and operational safety of the MIQ A is only guaranteed under the environmental conditions that are...

Страница 9: ...with plastic washer z 1 x contact base z 2 x plastic tapping screws for fixing the contact base z Operating manual 3 2 Installation in the IQ SENSOR NET General installation instructions The IQ SENSOR...

Страница 10: ...Installation MIQ A 10 ba75775e01 08 2008...

Страница 11: ...4 1 Maintenance The MIQ A requires no special maintenance The general maintenance of IQ SENSOR NET components is described in the IQ SENSOR NET system operating manual 4 2 Cleaning The cleaning of IQ...

Страница 12: ...Maintenance and cleaning MIQ A 12 ba75775e01 08 2008...

Страница 13: ...TA of the IQ SENSOR NET system operating manual Power consumption Approx 1 5 W Protective class III Number of MIQ A in a IQ SENSOR NET system 1 Applicable norms EN 61010 1 UL 3111 1 CAN CSA C22 2 No 1...

Страница 14: ...Technical data MIQ A 14 ba75775e01 08 2008...

Отзывы: