background image

AC LINE CONNECTIONS 
 

The AC Line connections should be connected to an AC mains source with a voltage of 
85VAC to 265V AC, operating at a frequency of 47Hz to 63Hz. The nominal operating 
voltage is normally 115VAC or 230VAC. The camera draws 50 Watts maximum, which 
translates to about 0.6 Amps at the worst case low line voltage of 85VAC. 
 
The “hot” side of the AC mains connections should applied to Pin U of the 18 pin MS 
connector. 
 
The “low” side of the AC mains connections should applied to Pin T of the 18 Pin MS 
connector. 
 
The AC mains safety ground connection should applied to Pin G of the 18 Pin MS 
connector. 
 

ETHERNET DATA AND VIDEO CONNECTIONS 

 
The PTZ camera control functions and video streaming functions to and from the 
SW720HV-H264-TI camera are transmitted over a 100Base-TX Ethernet connection 
using specific Ethernet ports assigned for each of the various functions and protocols. 
 
  

CAMERA PTZ CONTROL PROTOCOLS AND PORTS 

 

The SW720HV-H264-TI camera supports COHU, Pelco D, WTI, NTCIP and 
Web/ONVIF protocols over Ethernet and through the optional RS-485 data 
connections. 

 

The various protocols are accessed through the use of different port numbers 
when sending camera control commands to the Sidewinder using an Ethernet 
connection. 

 
  COHU 

Protocol: 

 

55002 

  Pelco 

Protocol: 

 

55001 

  WTI 

Protocol: 

  53935 

  NTCIP 

Protocol: 

 

55000 

  Web/ONVIF 

Protocol: 

55003 

 

OPTIONAL HARD WIRED PTZ CONTROL PORT

 

 

An optional hard wired RS-485 port can be configured on the SW720HV-H264-
TI camera for special situations. These signals are provided on pins M, N, R and S 
of the 18 pin MS connector and can be wired to the normally unused Blue and 
Brown twisted pairs on the CAT-5e extension cable (see wiring chart). This 
option MUST be ordered at time of purchase. 

 

SW720HV-H.264-TI   

 

WTI ~ Page 18 of 21

 

Содержание SW720HV-H.264-TI

Страница 1: ...SW720HV H 264 TI Installation and Operation Manual 11 14...

Страница 2: ...PROPER INSTALLATION 8 INSTALLATION PLANNING 8 DIMENSIONS AND MOUNTING 9 MECHANICAL DIMENSIONS 9 MOUNTING 10 MOUNTING ACCESSORIES 11 SIGNAL CONNECTIONS 17 AC LINE CONNECTIONS 18 ETHERNET DATA AND VIDEO...

Страница 3: ...R MORE INFORMATION WTI Wireless Technology Inc 2064 Eastman Avenue Suite 113 Ventura CA 93003 7787 TOLL FREE 866 gotowti 468 6984 TEL 805 339 9696 FAX 805 339 0932 EMAIL sales gotowti com INTERNET htt...

Страница 4: ...uthorized WTI Wireless Technology Inc Warranty Station This warranty shall not apply to appearance or accessory items including but not limited to knobs connectors cabinets and connecting cables This...

Страница 5: ...itten warranty please include a written explanation with the product when returned SHIP FREIGHT PRE PAID TO WTI Wireless Technology Inc 2064 Eastman Avenue Suite 113 Ventura CA 93003 7787 TEL 805 339...

Страница 6: ...ons herein for use of this equipment 4 Heed all warnings Adhere to all warnings on the equipment and in this manual 5 To reduce the risk of electric shock or equipment damage work on the unit only whe...

Страница 7: ...to 63Hz Ethernet 10 100Base T communication is used for transport of the video and control signals Power and Ethernet signals are provided via a 36 inch long bottom egress umbilical cable bundle usin...

Страница 8: ...are no physical obstructions in the way of any required viewing directions 5 Be sure that there is access to the end of the umbilical cable on the bottom of the camera to facilitate connecting and di...

Страница 9: ...DIMENSIONS AND MOUNTING MECHANICAL DIMENSIONS Bottom Egress Side Egress SW720HV H 264 TI WTI Page 9 of 21...

Страница 10: ...profile of the camera will no longer be able to naturally shed material to the sides The camera may NOT be mounted with the base facing horizontally The base of the Sidewinder SW720HV H 264 TI camera...

Страница 11: ...I manufactures several different mounts for the Sidewinder camera series that allow the camera to be attached to pole tops horizontal poles vertical poles and walls SWWM1 Wall Mount Option SW720HV H 2...

Страница 12: ...SWWM1 SWVPA Wall Mount with Vertical Pole Adapter SW720HV H 264 TI WTI Page 12 of 21...

Страница 13: ...SWPTM1 Pole Top Mount SW720HV H 264 TI WTI Page 13 of 21...

Страница 14: ...SWHPM1 Horizontal Pole Mount SW720HV H 264 TI WTI Page 14 of 21...

Страница 15: ...15 4 1430 6 x6 x3 8 Square Mounting Plate SW720HV H 264 TI WTI Page 15 of 21...

Страница 16: ...15 4 913 6 Round Riser Mounting Base SW720HV H 264 TI WTI Page 16 of 21...

Страница 17: ...Recommendations A Analog Video Ground RG 59U Shield B C D Tx Orange White CAT 5e E Tx Orange CAT 5e F Rx Green White CAT 5e G AC Safety Ground Green 22 AWG Minimum Same or heavier than AC Line Input H...

Страница 18: ...Ethernet connection using specific Ethernet ports assigned for each of the various functions and protocols CAMERA PTZ CONTROL PROTOCOLS AND PORTS The SW720HV H264 TI camera supports COHU Pelco D WTI...

Страница 19: ...AMING PROTOCOLS AND PORTS The SW720HV H264 TI camera supports the following video streaming formats on the following ports RTSP Server TCP 8554 RTP Video Data UDP Stream 1 18888 RTP Video Data UDP Str...

Страница 20: ...00W 40A transient voltage suppressor SEALING AND PRESSURIZATION The SW720HV H264 TI camera provides two levels of sealing and pressurization The entire camera including the base housing and camera tub...

Страница 21: ...SW720HV H 264 TI WTI Page 21 of 21 camera housing if an unregulated high pressure dry Nitrogen tank were to be connected to the Schrader valve...

Отзывы: