Small offsets between the calibrated value and the delivered
value in constant current may be nullified by adjusting the tenths
digit of Turns Ratio.
1F3CUd`_Y^d
AVC Setpoint
is the voltage value that the Automatic Voltage
Control algorithm pivots on. If set to 0, the AVC system is turned
off. If the control is in constant current mode, the LED next to
AVC Setpoint
on the DEP will not light. The AVC algorithm is
not used in Constant Current mode.
@b_WbQ]<_S[_ed
Program Lockout
is in several levels. To change the lockout level,
first close SW1–8 and in Program mode, choose a new level. The
new lockout level will be secured ONLY by reopening SW1–8.
After reopening SW1–8, when attempting to change a lockout
item, access is denied and "LOC" is displayed. Regardless of the
chosen lockout level, the operator can always select and display
any schedule data or select a schedule to run in Discrete pilot
mode. The lockout definitions are
•
Level 4: Full access.
•
Level 3: Full access except for certain restricted Config items.
•
Level 2: Full access except for all Config. items.
•
Level 1: Access ONLY to the WELD function
•
Level 0: No access.
>Udg_b[94
This is the unique address of the weld control on a RS-485
networked system. The range is 0 – 64, where 0 is off line.
3Q\<Y^UF_\dQWU
Line Voltage calibration
allows the user to enter a measured line
voltage value. The range for this instruction is 0 – 999 VAC. A
new value will be accepted ONLY when you
1.
Exit Cal Line Voltage or Program mode, and
2.
Answer the "?" (question, accept this new value?) by pressing
the FAULT RESET key. By pressing any other key, the control
will not scale itself to the new voltage value.
3Q\3ebbU^d
This is a current calibration entered in A. or kA. (A. x 1,000). The
range for this instruction is 0 – 999 A., then shifts to 1.00 –65.5 kA.
Appearance of the decimal point indicates the shift to kA. A new
value is accepted ONLY when you
1.
Exit Cal Current or exit Program mode, and
2.
Answer the "?" (question, accept this new value?) by pressing
the Fault Reset key. By pressing any other key, the control
will not scale itself to the new current value. See Chapter 8,
"Re-calibrating the T2050" for more details.
Содержание Technitron T2050
Страница 8: ...D 3_ db_ Ub 2_QbT Qi_ed _TYVYUT DUSX Ydb_ D GU T 3_ db_ Figure 1D 3_ db_ Ub 2_QbT Qi_ed ...
Страница 20: ...DXU 4QdQ 5 dbi Q U 45 _TYVYUT DUSX Ydb_ D GU T 3_ db_ Figure 4 45 fUb Qi GD3 _b ...
Страница 44: ...BU SQ YRbQdY W dXU D _TYVYUT DUSX Ydb_ D GU T 3_ db_ This page is intentionally left blank ...
Страница 52: ...1 YSQdY_ 5hQ U _TYVYUT DUSX Ydb_ D GU T 3_ db_ This page is intentionally left blank ...
Страница 54: ... _TYVYUT DUSX Ydb_ D GU T 3_ db_ This page is intentionally left blank ...
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......