/RFDO2XWSXWV
NO FAULT Output
This output is ON to indicate that the control is functioning
normally. If the control shuts down as the result of a fault
condition, this output will be turned OFF.
ALERT Output
This output is OFF to indicate that the control is functioning
normally. Alert conditions are usually less serious than faults
and are normally used to warn the operator that maintenance
is required.
ISOLATION CONTACTOR Output
The ISOLATION CONTACTOR output operates the weld
transformer isolation contactor. Output #12 on the SLC
output module informs the MFDC inverter when it is
required to pull in the charging pack.
The charging pack remains energized. It will drop out only
when an inverter fault is generated, or during an emergency
stop condition.
SHUNT TRIP Output
Activating this output trips the circuit breaker in case of a
catastrophic failure.
INITIATE ACKNOWLEDGE Output
This output indicates that a schedule is being executed by the
weld processor.