Individuals whose feet or legs are inflamed or have open wounds should not be allowed to use 
the  pedicure  spa  at  any  time.  Nail  technicians  should  advise  clients  to  consult  their  physician 
before  using  the  pedicure  spa  if  there  is  any  sign  of  fungal  infection,  swelling,  fracture,  or 
persistent pain. If the client experiences any pain or discomfort, immediately discontinue the use 
of the pedicure spa. 

Your client’s massage and pedicure spa experience should be pleasant and 

comfortable.

 

!

 

Warning

 

SAFETY & PRECAUTIONS 

 

PLEASE carefully read this entire manual before installation and use of the pedicure spa. If you have any questions or 
problems regarding the installation or use of this pedicure spa, please contact WS Industries, Inc. at 1-714-799-9882 or 
[email protected], before proceeding.

 

Installation  of  this  pedicure  spa  should  be  done  a  local,  licensed  plumber  and  licensed  electrician  to  ensure 
compliance with all your local and state building codes.

 

Safe  and  efficient  operation  of  this  pedicure  spa  cannot  be  ensured  unless  it  is  provided    with    adequate    electrical 
power,  sufficient  water  pressure,  proper  water  temperature,  and  required    drainage    capabilities.    Contact  your  local 
building  inspector  for  information  and  local  code  compliance  procedures  that  need  to  be  followed  when  having  your 
pedicure  spa  installed.  Subsequent  inspections    and    approvals    that    may    be    required  are  the  responsibility  of  the 
purchaser. (See limited warranty regarding incidental or consequential exclusions)

 

 
 
 
 

 

WARNING: RISK OF ELECTRIC SHOCK: do not permit ANY electric appliance to be operated in close of 

this pedicure spa

 

CAUTION: Test the ground fault circuit interrupter protecting this appliance periodically in accordance with 

the manufacturer’s instructions.

 

Temperatures sufficiently high to cause burns may occur regardless of the control  setting.

 

1

. Do not use on …

 

• 

Children or infants 

• 

People with have fallen asleep 

• 

People who have poor circulation 

• 

People who are diabetic 

Note: Check the skin in contact with the heated area of the pedicure spa frequently to reduce the risk       

of blistering.

 

Excessive water temperature is dangerous and should be checked before use. Maximum operating water 
temperature should not exceed 105 F and the maximum supply water temperature should not exceed 150  F.

 

The spa could have a heated surface in the seat back cushion. Persons sensitive to heat must be careful when 
using the spa.

 

Always enter and exit the pedicure spa slowly and carefully.

 

Close side arm rests before operating the chair.

 

Do not operate any electrical device while pedicure spa is in use.

 

This pedicure spa has a weight capacity of 250 pounds.

 

Use only while seated.

 

Connect  this  appliance  to  a  properly  grounded  outlet  only.

 

 

Note: Always verify maximum temperatures with your local & state codes.

 

 
 

 

Содержание FIORI 9000

Страница 1: ...OWNER MANUAL PLEASE SAVE THIS MANUAL FOR REFERENC 9000 2019 W S Industries Inc All rights reserved Design and Specifications are subject to change without notice ...

Страница 2: ...al Limited Warranty 3 Safety and Precautions 4 Installation Utility Information 5 Spa Diagram and Measurements 6 Unboxing and Wall Clearance 7 Installation Diamond Base 8 10 Installation Crystal Base 11 13 Care and Maintenance 14 ...

Страница 3: ...local plumbing electrical and building codes any damage resulting from standing in the basin or any other unintended stress to the basin any damage incurred during shipping and handling This limited warranty is also conditional upon the pedicure spa being installed by a licensed professional in accordance with WS installation instructions the proper use of cleaning and sanitizing solutions as per ...

Страница 4: ...ng your pedicure spa installed Subsequent inspections and approvals that may be required are the responsibility of the purchaser See limited warranty regarding incidental or consequential exclusions WARNING RISK OF ELECTRIC SHOCK do not permit ANY electric appliance to be operated in close of this pedicure spa CAUTION Test the ground fault circuit interrupter protecting this appliance periodically...

Страница 5: ...t and Basin Extended 68in X 34in X 54in Reclined and Basin Extended 81in X 34in X 40in Weight Capacity 350lbs Basin Capacity Diamond Bowl 5 25 Gallons Crystal Bowl 6 Gallons Plumbing Water Supply Lines Hot Cold supply lines are 1 2 with standard faucet fitting Drain Pipe Outlet 1 Schedule 40 PVC Coupler Gravity type drainage systems do not require back flow fitting Optional discharge pump wall dra...

Страница 6: ...Pedicure Spa Diagram And Measurements ...

Страница 7: ...t with removing the 4 thinner boxes on the side you will need 2 people to help remove the box from the top Approx 160lbs the middle 2 boxes are the basins Be careful not to drop or have anything dropped on these boxes as they are glass and fragile Once the boxes are removed from the pallet Carefully remove strap on massage chair box and lift the carton over the chair Remove the rest of the packing...

Страница 8: ...nge see picture Please allow glue to fully set prior to use See directions on glue bottle Mounting the brackets The shorter flanged motor bracket is to be mounted in the center of the spa chair using the 3 rd and 5 th holes from the motor bracket see picture using the two 1 bolts The taller flanged drain pipe bracket is to be mounted to the left of the motor bracket using the same 3 rd and 5 th ho...

Страница 9: ...s pin and clip Connect the 2 wiring harnesses 1 black and 1 white to the spa chair Turn on spa chair and push and hold the left arrow button to send the push rod forward until it stops Install Bearing Block Guide using the 4 longer 1 bolts and Allen wrench tool provided ...

Страница 10: ...n and clip Run the hot and cold supply lines underneath control box and fasten the drain pipe to the threaded drain on the rear of the spa Mount the rear of the drain pipe to the drain mounting bracket using the smaller clevis pin and clip If extension cords are required please be sure to use a 12 gauge cord ...

Страница 11: ...ture Please allow glue to fully set prior to use See directions on glue bottle Mounting the brackets The shorter flanged motor bracket is to be mounted in the center of the spa chair using the 2nd and 4th holes from the motor bracket see picture using the two 1 bolts The taller flanged drain pipe bracket is to be mounted to the left of the motor bracket using the same 2nd and 4th holes also with t...

Страница 12: ...d until it stops Push basin under chair and align the push rod assembly to the rear of the basin attach using large clevis pin and clip Run the hot and cold supply lines underneath control box and fasten the drain pipe to the threaded drain on the rear of the spa Mount the rear of the drain pipe to the drain mounting bracket using the smaller clevis pin and clip If extension cords are required ple...

Страница 13: ...al connections for cracks leaks ordamage Wipe down chair basin with damp cloth to preventstains Dust clean control box with dry cloth or duster to preventoverheating Periodic Maintenance Inspection lubrication of massage roller and track is required every 6 months to ensure proper function and long service life Prior to inspection please ensure that the unit is off andunplugged To get to massage r...

Страница 14: ...WWW WSNAILS COM W S INDUSTRIES INC 14063 BORATE ST SANTA FE SPRINGS CA 90670 TEL 1 714 799 9882 FAX 1 174 890 0383 EMAIL INFO WSNAILS COM ...

Отзывы: