background image

 

 

Hyperion Wireless PDU  Installation Guide

 

www.wrensolutions.com

 

7L778 Rev A 200428

 

A

BOUT

 

THIS

 D

OCUMENT

 

This document pertains to installation of the Hyperion Perimeter 
Detection Unit (HYP-PP180R-B). Before installation, please familiarize 
yourself with this installation guide and review the Hyperion User 
Guide to understand system configuration and setup.   
  

P

RODUCT

 M

ODIFICATIONS

 

This product is to be installed and used for the specific purpose for 
which it was designed.  It is not to be modified or serviced by anyone 
other then Wren.  Unauthorized changes or modifications to the 
product will result in the warranty being voided and could possibly 
invalidate regulatory certifications. 
 

W

ARRANTY

 

Unless otherwise noted, all products are covered by Wren's Standard 
Limited Manufacturer's Warranty as set forth in the current version of 
Wren's 

Terms and Conditions

 

  

I

NTELLECTUAL

 P

ROPERTY

 R

IGHTS

 

Wren maintains certain intellectual property rights that may pertain to 
this product.  To see a list of our patents, please refer to our  
 

T

RADEMARK

 A

CKNOWLEDGMENTS

  

Wren®. the Wren logo, Hyperion® and the Hyperion logo are 
trademarks of Wren. The trademarks that are followed by ® are 
registered trademarks in the U.S. All other trademarks and/or 
registered trademarks mentioned herein are properties of their 
respective owners and are for reference purposes only. The use of 
such third party trademarks does not indicate any affiliation with or 
sponsorship of or by Wren. All rights reserved. 

 
 

N

OTICES

 

 
RF Exposure for FCC  

WARNING

To satisfy FCC RF exposure requirements for mobile 

transmitting devices, a separation distance of 31 cm or more should be 
maintained between the antenna of this device and persons during 
device operation. To ensure compliance, operations at closer than this 
distance is not recommended. The antenna used for this transmitter 
must not be co-located in conjunction with any other antenna or 
transmitter. 
 

RF Exposure for IC  
WARNING

To satisfy IC RF exposure requirements for mobile 

transmitting devices, a separation distance of 44 cm or more should be 
maintained between the antenna of this device and persons during 
device operation. To ensure compliance, operations at closer than this 
distance is not recommended. The antenna used for this transmitter 
must not be co-located in conjunction with any other antenna or 
transmitter. 
 

AVERTISSEMENT

Pour satisfaire IC RF exigences d’exposition pour 

les appareils mobiles de transmission,  une distance de séparation de 44 

cm ou plus doit être maintenue entre l’antenne de cet appareil et des 
personnes pendant le fonctionnement de l’appareil. Pour assurer la 

conformité, les opérations au plus près que cette distance ne sont pas 

recommandés. L’antenne utilisée pour cet émetteur ne doit pas être

 

situé en conjonction avec une autre antenne ou émetteur

(800) 881

-

2249

 

P

RODUCT

 S

UPPORT

 

For comprehensive product support including manuals, FAQs and troubleshooting, visit our customer support portal.

 

WWW.WRENSOLUTIONS.COM

 

/HYPERION/HYPERION

-

SUPPORT

 

Содержание HYPERION HYP-PP180R-B

Страница 1: ...Hyperion Wireless PDU Installation Guide www wrensolutions com 7L778 Rev A 200428 INSTALLATION GUIDE HYPERION PERIMETER DETECTION HYP PP180R B ...

Страница 2: ...ndicate any affiliation with or sponsorship of or by Wren All rights reserved NOTICES RF Exposure for FCC WARNING To satisfy FCC RF exposure requirements for mobile transmitting devices a separation distance of 31 cm or more should be maintained between the antenna of this device and persons during device operation To ensure compliance operations at closer than this distance is not recommended The...

Страница 3: ...OMPONENT LIST REQUIRED TOOLS AND ACCESSORIES 2 Phillips screwdriver Drill Cables CAT5 or higher IDENTIFY DEVICE MOUNTING LOCATION 1 Mounting Surface The PP180 should be mounted to a structurally solid vertical wall surface Mounting to a horizontal ceiling surface is not recommended and will negatively impact device performance Mounting Height Hyperion PDU Power Supply Hyperion Radio w antenna ...

Страница 4: ...he immediate vicinity of the radio and antenna We suggest a minimum 3 foot zone surrounding the area Mounting Height The minimum recommended mounting height for the Hyperion Radio is 10 feet from ground level Mounting heights over or under 10 feet are acceptable but the areas must be free and clear of any obstructions NOTE OBSTRUCTIONS WILL NEGATIVELY IMPACT RADIO PERFORMANCE ENSURE THAT THERE ARE...

Страница 5: ...ize fasteners and the appropriate wall anchors if required Re install the upper positioning screws Position the device to the appropriate angle identified in Step 1 Mount to the desired location using 8 size fasteners and the appropriate wall anchors if required Attach the antenna to the radio and position for maximum reception NOTE OBSTRUCTIONS WILL NEGATIVELY IMPACT RADIO PERFORMANCE ENSURE THAT...

Страница 6: ...minimum CAT5 rated and at least 24AWG Cabling Procedure Run a length of CAT5 or greater cabling from IHYP PP180R B to the Hyperion Radio Crimp RJ45 connectors to each end of the ca ble run if needed Certify that the cabling meets the T 568A standard 5 WALL PENETRATION PREP Drill an appropriate sized wall penetration to pass a CAT5 ethernet cable from the device to the radio ...

Страница 7: ...EEN CERTIFIED BEFORE ATTACHING TO ANY DEVICES 7 CONNECTING DEVICES 9 CONNECT POWER Use the provided power supply to apply power the radio 8 CONNECT DEVICE DATA Connect the CAT5 cabling to the device and to the radio 10 ADD DEVICE TO THE GATEWAY The device is now powered on and ready to be added to Hyperion Refer to the Hyperion User Manual for setup details ...

Отзывы: