Rev 29.0/11-19
P1-DC: #35111
27
B
ATTERY
R
ECHARGE
Charge the battery whenever the battery gauge shows reduced energy.
Caution: Make sure
valve handle is in “release” position
(
/
power off).
Make sure power source has ground fault circuit
interrupter.
Identify the input voltage
marked on the battery
charger, and plug it in to an
appropriate power source.
1
The power lamp (
Ф
) turns on when the charger is functioning. Consult the six-stage display to
determine the charging status. The battery can be used after stage 3 and is fully charged at
stage 5.
Normally, the battery should take no more than 8 hours to charge completely.
2
If not, check for
the following faults:
• Power lamp (
Ф
) flashes:
Charger is not
connected to battery;
reconnect charger (see
“ASSEMBLY” on page 8).
• Error lamp (!) turns on
immediately: Battery
leads connected to
wrong poles; reverse
battery leads.
• Charging stops at stage
1 or 4, and error lamp
(!) turns on: Battery is
no longer functioning; replace battery (see “REPLACEMENT PARTS” on page 28).
Before you return the lifter to service, recheck the battery as previously directed.
1..... Any external power supply must conform to all applicable local codes. This lifter is not intended for use while the charger is connected to AC
power.
2..... The charger automatically reduces the charging rate when the battery is fully charged.
MAINTENANCE
Содержание P110C04DC
Страница 2: ...P1 DC 35111 Rev 29 0 11 19 2...
Страница 6: ...P1 DC 35111 Rev 29 0 11 19 4 SPECIFICATIONS Note A standard P11104DC is shown...
Страница 32: ...P1 DC 35111 Rev 29 0 11 19 30...
Страница 33: ...Rev 29 0 11 19 P1 DC 35111 31...
Страница 34: ...P1 DC 35111 Rev 29 0 11 19 32...
Страница 35: ......
Страница 36: ......