Monitoring Vacuum Indicators
The vacuum lift light and the vacuum gauge must remain completely visible to the operator, so
that they can be monitored throughout the entire lift.
WARNING: Vacuum indicators must be visible to operator throughout entire lift.
The lifter’s vacuum pump runs continuously to maintain sufficient vacuum for lifting the
maximum load weight. If the vacuum system experiences leakage while the lifter is attached to
the load, the lift light turns off automatically, to signal the reduction in vacuum to the operator.
If the lift light turns off while you are lifting a load, make sure the vacuum gauge shows a
vacuum level of 16" Hg [-54 kPa] or higher. If not, move away and stay clear of the load until it
can be lowered to the ground or a stable support.
WARNING: Stay clear of any suspended load while vacuum level is lower than
16" Hg [-54 kPa].
Discontinue lifter use until the cause of the vacuum loss can be determined. If the lift light does
not turn on when the lifter is attached to clean, smooth, nonporous materials, the leakage is
likely to be in the vacuum system. In this event, perform the V
ACUUM
T
EST
(see MAINTENANCE)
and inspect the vacuum pads for damage (see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
:
Inspection). If the vacuum loss cannot be remedied immediately, perform inspection and
maintenance as needed to identify and correct any deficiency before resuming normal operation
of the lifter.
Controlling the Lifter and Load
When the vacuum indicators show that the lifter is ready, use the hoisting equipment to raise the
lifter and load as needed to clear any obstacles in their path. Use the control handles to keep the
lifter and load in the desired orientation while they are suspended from the crane. Once
sufficient clearance is established, the load can be rotated or tilted as desired (see T
O
R
OTATE THE
L
OAD
E
DGEWISE
or T
O
T
ILT THE
L
OAD
to follow).
In Case of Power Failure
The lifter is equipped with a vacuum reserve tank, designed to maintain vacuum temporarily in
case of a power failure.
WARNING: Stay clear of any suspended load in the event of a power failure.
Although the lifter is designed to support the load for at least 5 minutes without power, this
depends on many factors, including the condition of the load and the lifter’s vacuum system (see
INTENDED USE: L
OAD
C
HARACTERISTICS
and MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
,
V
ACUUM
T
EST
). If a power failure occurs, keep all personnel clear of the suspended load until it can safely
be placed on the ground or a stable support. Correct any deficiency before resuming normal
operation of the lifter.
Содержание MRPT1211LAC
Страница 2: ......
Страница 31: ...Rev 2 0 4 16 29 MRPT1211LAC 35063 ...
Страница 32: ...Rev 2 0 4 16 30 MRPT1211LAC 35063 ...
Страница 33: ...Rev 2 0 4 16 31 MRPT1211LAC 35063 ...
Страница 34: ...Rev 2 0 4 16 32 MRPT1211LAC 35063 ...
Страница 35: ...Rev 2 0 4 16 33 MRPT1211LAC 35063 ...
Страница 36: ...Rev 2 0 4 16 34 MRPT1211LAC 35063 ...
Страница 37: ...Rev 2 0 4 16 35 MRPT1211LAC 35063 ...
Страница 38: ...Rev 2 0 4 16 36 MRPT1211LAC 35063 ...