FL1-DC: #35026
Rev 6.0/11-20
16
Controlling the Lifter and Load
1A
When the lifter is ready, use the hoisting equipment to raise
the lifter and load as needed.
Use the control handle (circled in fig. 1A) to keep the lifter
and load in the required position.
Once there is enough clearance, you may move the load as
required.
In Case of a Power Failure
A vacuum reserve tank helps maintain vacuum temporarily in the event of a battery failure or
electrical system failure. Although the lifter is designed to support the load for at least 5
minutes without power, this depends on many factors, including the
and the condition of the vacuum pad (see
).
Stay clear of any suspended
load during power failure.
If a power failure occurs, keep everyone away from a
suspended load until it can be safely lowered to a stable
support. Correct any faults before resuming normal
operation of the lifter.
OPERATION
Содержание FL1HV11DC
Страница 2: ...FL1 DC 35026 Rev 6 0 11 20 2...
Страница 6: ...FL1 DC 35026 Rev 6 0 11 20 4 SPECIFICATIONS...
Страница 30: ...FL1 DC 35026 Rev 6 0 11 20 28...