Preparing unit COOLIUS-HP for operation
WARNING!
The presence of the synoptic sticker does not exempt the operator from carefully reading this manual and
strictly observing the described procedures.
3.1
Checking the vacuum pump oil level
Before checking the oil level, the unit must be placed on a level surface and its power supply must be turned
off.
The user must check that the vacuum pump oil level covers half of the sight glass (see drawing below).
3.2
Turning COOLIUS-HP unit on for the first time
1.
Place the 87 switch on position 1
2.
The unit will automatically ask for the interface language; select the language by means of the
arrows and confirm with
.
3.
Then, the zeroing of all the scales will start. The process is completely automatic and will take about 1
minute.
4.
At the end of the procedure, the values of the scales will appear on the display.
Standby screen 1
Standby screen 2
5.
The next times you will turn the unit on, the display will show the software and hardware version of the
unit and the standby screen will appear right away.
R
1
3
4
a
0
.
0
0
0 k g
Ξ
1
0
:
3
4
0
8
/
1
0
/
1 2
▼
O
l
i
o
i
n
0 g
▲
O
l
i
o
o
u t
0 g
Ξ
Содержание COOLIUS 4000 HP
Страница 1: ...2154 ENG Version 02 2014 User s manual COOLIUS 4000 HP automatic a c service unit Art No W050200011 ...
Страница 2: ......
Страница 5: ...3 32 Layout drawings Picture 1 ...
Страница 6: ...4 32 Picture 2 ...
Страница 7: ...5 32 Hydraulic diagram Picture 3 ...
Страница 8: ...6 32 Electric diagram Picture 4 ...
Страница 29: ...27 32 ...
Страница 31: ......