Worx WG518E Скачать руководство пользователя страница 9

9

Electric Blower 

WG518E

Using the Blower

Hold the blow tube approximately 

8—20cm above the ground when 

operating the tool.

Use a sweeping motion from side 

to side. Advance slowly keeping the 

accumulated debris/leaves in front 

of you.

After blowing the debris/leaves into 

a pile, it is easy to dispose of the 

pile.

CAUTION!

—Do not blow hard objects such as 

nails, bolts, or rocks.

—Do not operate the blower near 

bystanders or pets.

—Use extra care when cleaning 

debris from stairs or other tight 

areas.

—Wear safety goggles or other 

suitable eye protection, long pants 

and shoes.

See Fig. D

Adjusting the Blowing Speed 

Variable Speed Switch

See Fig. E

STORAGE

Store the blower and extension cord indoors, in 

a cool dry location, out of reach of children and 

animals.

CLEANING THE TOOL

Clean the tool regularly.

WARNING!

 Keep your product dry.

Under no circumstances spray with water.

—   To clean the tool, use only mild soap and a damp  

cloth.

—  Do not use any type of detergent, cleaner or 

solvent which may contain chemicals that could 

seriouslydamage the plastic.

—  Self lubricating bearings are used in your 

product,   therefore lubrication is not required.

ENVIRONMENTAL 

PROTECTION

Waste electrical products must not be disposed 

of with household waste. Please recycle where 

facilities exist. Check with your local authorities 

or retailer for recycling advice.

PLUG REPLACEMENT 

(ONLY FOR REWIRABLE 

PLUG OF UK & IRELAND)

If you need to replace the fitted plug then follow the 

instructions below.

IMPORTANT

The wires in the mains lead are colored in 

accordance with the following code:

Blue = Neutral

Brown = Live

As the colors of the wires in the mains lead of this 

appliance may not correspond with the colored 

markings identifying the terminals in your plug, 

proceed as follows. The wire which is colored blue 

must be connected to the terminal which is marked 

with N. The wire which is colored brown must be 

connected to the terminal which is marked with L.

WARNING: 

Never connect live or neutral 

wires to the earth terminal of the plug. Only 

fit an approved 13ABS1363/A plug and the correct 

rated fuse.

NOTE: 

If a moulded plug is fitted and has to be 

removed take great care in disposing of the plug 

and severed cable, it must be destroyed to prevent 

engaging into a socket.

Connect

Blue to N

(neutral)

Outer sleeve

firmly clamped

Cable grip

Brown L (live)

13 Amp fuse approved
to BS1362

Содержание WG518E

Страница 1: ...Electric Blower WG5 1 8E SAFETY AND OPERATING MANUAL ORIGINAL INSTRUCTIONS ...

Страница 2: ......

Страница 3: ...C A Click Click B 1 2 D 2 1 3 4 5 6 7 ...

Страница 4: ...E I II D C ON OFF ...

Страница 5: ...ts are nearby d Keep in mind that the operator or user is responsible for accidents or hazards occurring to other people or their property 2 Preparation a While operating the machine always wear substantial footwear and long trousers Do not operate the machine when barefoot or wearing open sandals Avoid wearing clothing that is loose fitting or that has hanging cords or ties b Do not wear loose cl...

Страница 6: ...he discharge zone when operating this machine f If the machine should start making any unusual noise or vibration immediately shut off the power source and allow the machine to stop Disconnect the machine from the supply and take the following steps before restarting and operating the machine Inspect for damage Replace or repair any damaged parts Check for and tighten any loose parts g Do not allo...

Страница 7: ...ow the machine to cool before making any inspections adjustments etc Maintain the machine with care and keep it clean f Store the machine in a dry place out of the reach of children g Always allow the machine to cool before storing h Never attempt to override the interlocked feature of the guard 5 Recommendation The machine should be supplied via a residual current device RCD with a tripping curre...

Страница 8: ...tool and ensuring it is sharp and in good condition The tightness of the grip on the handles and if any anti vibration accessories are used And the tool is being used as intended by its design and these instructions This tool may cause hand arm vibration syndrome if its use is not adequately managed WARNING To be accurate an estimation of exposure level in the actual conditions of use should also ...

Страница 9: ... used in your product therefore lubrication is not required ENVIRONMENTAL PROTECTION Waste electrical products must not be disposed of with household waste Please recycle where facilities exist Check with your local authorities or retailer for recycling advice PLUG REPLACEMENT ONLY FOR REWIRABLE PLUG OF UK IRELAND If you need to replace the fitted plug then follow the instructions below IMPORTANT ...

Страница 10: ...011 65 EU 2000 14 EC amended by 2005 88 EC 2000 14 EC amended by 2005 88 EC Conformity Assessment Procedure as per Annex V Measured Sound Power Level 100 1dB A Declared Guaranteed Sound Power Level 101dB A Standards conform to EN 60335 1 EN 50636 2 100 EN ISO 3744 EN 62233 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 The person authorized to compile the technical file Name Russell Nicholson Add...

Страница 11: ......

Страница 12: ...Copyright 2016 Positec All Rights Reserved AR01264400 www worx com ...

Отзывы: