15
5.3. front WeLDInG paneL "MIxtes" 5.4. front WeLDInG paneL "arc"
paneL DescrIptIon
1 - earth socket
2 - Socket for low range welding (*)
3 - Socket for high range welding
4 - Function mode selector
5 - Rated value selector
operatIon as a Generator
•
Turn selector 4 to "GeN.".
•
Turn selector 5 to the desired voltage.
•
Connect the user to the sockets.
•
Start the user device.
operatIon as a WeLDer
•
Turn selector 4 to "WeLD".
•
Insert the earth jack cable in the socket 1.
•
Connect the earth cable to the part that is to
be welded.
•
Insert the jack of the electrode holder cable
in socket 2 (*) or 3 depending on the current
range desired.
•
Set the current range with the selector 3.
•
Set the welding current with the selector 5
(blue scale for the low range(*),red scale for
the high range).
•
Weld.
During welding the generator sockets are
live, but the voltage value is low and unstable.
So, for safety reasons, it is recommended to
disconnect the user loads during welding.
The welding machine can give the maximum
current only for a limited time, after which it
must be allowed to cool (see indication on the
plate). So, when working with high currents, if
the thermal protection trips, you must wait a few
minutes for it to be set automatically.
paneL DescrIptIon
1 - earth socket
2 - Rated value selector
3 - Range selector
4 - Socket for welding
operatIon as a Generator
•
Turn selector 3 to "GeN." (except eW 200 DC
and eW 210 DC for which the selector position
is immaterial).
•
Connect the user to the sockets.
•
Start the user device.
operatIon as a WeLDer
•
Insert the earth jack cable in the socket 1 (4 to
weld with inverse polarity).
•
Connect the earth cable to the part that is to
be welded.
•
Insert the jack of the electrode holder cable in
the other socket.
•
Set the current range with the selector 3.
•
Set the welding current with the selector 2
(black scale for the low range, blue scale for
the medium range(*),red scale for the high
range).
•
Weld.
During welding the generator sockets are
live, but the voltage value is low and unstable.
So, for safety reasons, it is recommended to
disconnect the user loads during welding.
The welding machine can give the maximum
current only for a limited time, after which it
must be allowed to cool (see indication on the
plate). So, when working with high currents, if
the thermal protection trips, you must wait a few
minutes for it to be set automatically.