Input voltage selection
※
220V
380V
440V
Output Connection (Front of the machine)
●
Connect the work cable (which is connected to the work clamp) to the
METAL terminal.
․
To connect the TIG torch, connect a electrode cable to the
TORCH terminal and a torch switch
․
connector to the torch switch receptacle and a gas connector to the output gas receptacle.
If you want to connect the remote controller, connect the connector of remote controller to REMOTE
․
CONTROL terminal.
If the water cooling unit is installed, connect the water input hose of water cooled torch to WATER OUT
․
terminal of welder.
․
Verify the connection of voltage selection terminal.
If necessary to change it,
√
Remove the cover of input voltage selection plate.
․
Position the wires for the voltage to be supplied from main power.
․
For 380V and 440V input, position a switch for the voltage would be used which is rear.
․