Open the cover of terminal and connect the power cable to the power input terminal on
․
the rear of the machine and close the cover of terminal. For grounding the machine,
connect a ground wire to the ground terminal marked with the symbol is located on the
rear panel of the machine.
Connect a power cord of gas regulator to the 110V outlet on rear of the machine.
․
Output Connection (Front of the machine)
●
Connect the work cable to the "
METAL" terminal.
․
To connect the Wire feeder, connect a electrode cable from wire feeder to the "
TORCH" terminal and
․
a Remote control cable from the wire feeder to the "REMOTE CONTROL" receptacle.
Install a gas regulator on a gas tank and connect a gas hose of extension cable from wire feeder to the
․
gas regulator on gas tank.
CO
2
Torch connection to wire feeder
Connect a wire feeding cable of torch to the wire feeding cable receptacle of wire feeder.
․
Connect a torch switch connector of torch to the torch switch receptacle of wire feeder.
․
Connect a gas hose of torch to the gas hose receptacle of wire feeder.
․