Input voltage selection
※
220V
380V
440V
To connect the power cables, turn the power switch OFF
․
Verify the voltage to be supplied from main power.
․
․
Verify the connection of voltage selection switch. If necessary to change it, remove the
cover of voltage selection switch and turn the switch to correct voltage to be
supplied from main power. Close the cover.
Open the cover of terminal and connect the power cable to the power input terminal on
․
the rear of the machine and close the cover of terminal. For grounding the machine,
connect a ground wire to the ground terminal marked with the symbol is located on the
rear panel of the machine.
Connect a power cord of gas regulator to the 110V outlet on rear of the machine.
․
Output Connection (Front of the machine)
●
Connect the work cable to the "
METAL" terminal.
․
To connect the Wire feeder, connect a electrode cable from wire feeder to the "
TORCH" terminal and
․
a Remote control cable from the wire feeder to the "REMOTE CONTROL" receptacle.
Install a gas regulator on a gas tank and connect a gas hose of extension cable from wire feeder to the
․
gas regulator on gas tank.
CO
2
Torch connection to wire feeder
Connect a wire feeding cable of torch to the wire feeding cable receptacle of wire feeder.
․
Connect a torch switch connector of torch to the torch switch receptacle of wire feeder.
․
Connect a gas hose of torch to the gas hose receptacle of wire feeder.
․
․
Verify the connection of voltage selection terminal.
If necessary to change it,
√
Remove the cover of input voltage selection plate.
․
Position the wires for the voltage to be supplied from main power.
․
For 380V and 440V input, position a switch for the voltage would be used which is rear.
․