AUDEMAT DAB Probe 2.1.x User Manual – 06/2019
Page 40
WorldCast Systems SAS - 20, avenue Neil Armstrong – 33700 Merignac – Bordeaux Métropole (France)
+33 (0)5 57 928 928 –
[email protected] – www.worldcastsystems.com
A.3.3.
Readings
Readings table
This part lists the various readings performed by the DAB Probe.
It indicates the name of the reading, its unit and the factor to apply (if any).
Name
Syntax
Access
GET - Possible value(s)
OID
readingsNameColumnId
STRING
N/A
Index of the measurement: 0 to 7
(number of collected RF measurements)
readingsName
STRING
Read Only
Measurement Type
.1.3.6.1.4.1.5299.15.29.1.8.3.1.1.2.measureIndex
readingsNameUnit
STRING
Read Only
Unit and factor of the measurement
.1.3.6.1.4.1.5299.15.29.1.8.3.1.1.3.measureIndex
Readings values table
This part gives the values of the RF readings performed by the DAB Probe (including factor when applicable).
Name
Syntax
Access
GET - Possible value(s)
OID
readingsValuesRowId
INTEGER
N/A
0 (index of the 1
st
MUX)
to x (last monitored MUX)
(See Channel table)
readingsValuesColumnId
INTEGER
N/A
Index of the measurement: 0 to 7
(number of collected RF measurements)
readingsValues
INTEGER
Read Only
Value of the measurement (including factor)
.1.3.6.1.4.1.5299.15.29.1.8.3.2.1.3.channelIndex.measureIndex