Operating pressure gauge (Fig. A, 7): This measuring instrument measures
the operating pressure. The operating pressure can be set with the reduc-
ing valve.
Safety valve (Fig. A, 9): If the pressure switch on the motor fails to switch
off when the motor reaches the preset pressure, the valve automatically
springs open in order to prevent overpressure. To open it manually, pull
on the ring on the valve in order to relieve the air pressure in the tank.
Regulating operating pressure
Fig. D
There is no need to always use the maximum operating pressure as most
compressed air tools have low pressure requirements. The correct operat-
ing pressure must be set on compressors fitted with a pressure reduction
device. The operating pressure can be set with the help of the pressure
regulator (5).
•
Turn clockwise to increase the pressure.
•
Turn anticlockwise to reduce the pressure.
After use
•
Switch off the equipment after use.
•
Pull the mains plug out of the socket when the equipment is not
being used.
•
Allow the equipment to cool down after use.
•
If necessary, disconnect and stow away any attachments and
accessories.
Maintenance
Pull out the plug before carrying out maintenance work on the
compressor.
This device has been designed for long-term operation with minimal
maintenance. Consistently satisfactory operation depends on correct
WAC_3050_1_EX_GB_SPK7.indb 16