J0Z-SP38-1016/90891
AFTER-SALES SERVICE
GB 0845 872 2740
www.coreservice.co.uk
IRL 019022605
Operation
5
Switching the tool on
CAUTION! Risk of electric shock!
Risk of electric shock.
• Before starting work on walls, floors or similar surfaces, ensure that all power lines
in the working area are switched off at the main switch cabinet.
1.Check the working area for pipes or cables (electricity, water, gas). It may be useful to use a
suitable tool for this such as a metal or a wire and pipe detector or to consult with a qualified
electrician or a utility company.
2. Wear protective clothing as well as eye and ear protection.
3. Ensure that the instrument is securely fitted.
4. Release the safety lock with the switch (7) and select a direction of rotation.
5. Press the ON / OFF switch (8) to switch the tool on.
• Hold the ON / OFF switch (8) for continuous operation.
• Pressing the ON / OFF switch controls the rotational speed. The more you
press the ON / OFF switch, the higher the rotational speed.
• While the tool is in operation, the LED work lamp (6) is activated to light up the work piece.
When drilling, note the following points:
• Always keep the tool at a 90° angle to the work piece.
• First place the drill bit on the work piece and then switch the tool on.
• If the drill twists in the work piece, change the direction of rotation and remove the
drill bit. Do not exert excessive pressure when drilling. When drilling, note the following
points:
• Always keep the tool at a 90° angle to the work piece.
• Note the direction of rotation of the screw. Pre-drill holes in hard materials.
CAUTION! Risk of eye injury!
Never direct the light beam at people or animals and
never look directly into the beam of the LED work light (6).
CAUTION! Risk of burning!
While drilling, the instrument and the work piece may become extremely hot, thus
creating the risk of burning.
• Wait a few minutes and let the instrument and work piece cool down before you
continue working.
• Put on gloves.