Страница 1: ...RVICE UK 0800 328 6020 Info globaltronicssupport com GT MM 10 E46106 09 13 Ireland 00800 4467 5888 Multi Sensor Stud Detector User Guide Multi Sensor UK WORKZONE E46106 book Seite 1 Montag 22 April 20...
Страница 2: ...cordance with these operating instructions the envisaged protection can be impaired Please keep these instructions and pass them on to other users Technical data Model GT MM 10 Battery size 9 V Block...
Страница 3: ...lities or lacking experience and or knowledge unless they are supervised by a person responsible for their safety or have received instructions for use of the device from this person in advance Superv...
Страница 4: ...and mucous membranes When coming into contact with battery acid immediately rinse the affected areas with plenty of clear water and immediately contact a physician Remove the batteries from the device...
Страница 5: ...push the battery onto the connector with the correct polarity 2 Insert the battery into the compartment and close the battery compartment lid again The battery status appears in the display when the...
Страница 6: ...n the area of electric cables once the power supply is disconnected at the consumer unit If in doubt seek the advice of an electrician The detected object can be wider or narrower than shown in the di...
Страница 7: ...to the object or directly on the wood the calibration can fail If the calibration fails the LC display shows the following symbol and a long beeping tone sounds Please switch the device on again in o...
Страница 8: ...object Continue moving the device in the same direction until no bar or min 1 bar appears in the display Then move the device in the opposite direction in order to mark the other edge of the object P...
Страница 9: ...tive electric cables that run close to one another can prevent the distinct detection of the individual objects The device also measures hidden posts slats and metal in walls up to a depth of 38 mm in...
Страница 10: ...ed with the greatest care The warranty period is three years from the date of purchase Please retain the sales receipt as proof of purchase as without it the warranty claim cannot be processed During...
Страница 11: ...nd your completed Warranty Card to Dario London Service Centre PO BOX 1125 Bromley BR1 9TW UK Hotline UK 0800 328 6020 Hotline Ireland 00800 4467 5888 Mail info globaltronicssupport com CUSTOMER SERVI...