When you use digital control (DMX or RS 485, you
MUST
make a short circuit
using a cable between + and Vo pins in the Analog input. The purpose of this
is to avoid that the amplifier considerer a noise introduced in the analogic
input as audio level.
ON
To another
DMX device
Power Supply
(24 V DC / 2 A)
0-10 V
Analog control
AUDIO OUTPUT (Channel L)
25W 4 max.
Ω
AUDIO OUTPUT (Channel R)
25W 4 max.
Ω
AUDIO IN (Channel L)
AUDIO IN (Channel R)
DMX Controller
or
RS485/ASCII
Commands
#nnnMUTx:\
It pass to MUTE condition the channel marked by “x” (1 or 2). If “x” does not write, both channels will pass to
MUTE condition.
#nnnUMUTx:\
The channel marked as “x” will leave MUTE condition. If “x” does not write, both channels will leave MUTE
condition.
#nnnTOGG:\
This command alternate both channels between MUTE & UNMUTE depending on the state of each one.
SLA Series (SLA 50 - SLA 300) User Manual/Manual de Instrucciones Pag 3
EN
CONNECTION EXAMPLE
WARNING !!
Connection example using SLA 50. The connections are
the same for SLA 300