Work Pro SPS 8 Скачать руководство пользователя страница 1

 

 

 

 

 

Paging Station 

SPS 8 sept 2016

 

 

 

 

Содержание SPS 8

Страница 1: ...Paging Station SPS 8 sept 2016 ...

Страница 2: ...Content 1 Overview 2 Connections 3 Basic use and configuration 4 Use and advanced settings ...

Страница 3: ...w The SPS 8 is a paging station designed specifically for the BlueLine system and is compatible with DigiLine This guide describes the features of the SPS 8 as well as its functionality Dimensions 210 x 40 x 135 mm Weight 620g ...

Страница 4: ...CONNECTIONS 2 SPS 8 connection ports ...

Страница 5: ...DIX Euroblock A connection to connect the external power supply source 5VDC and the alarm System It is usually an open contact It can be programmed with one or several OSC commands that can be assigned to the alarm event Euroblock B connection to connect to the the monitor audio output The signal provided by this connection is the same that the one of the Ethernet It is an unbalanced audio output ...

Страница 6: ...to Talk button Placed on the low part of the central zone of the control board when pressed every device which has been previously selected through the zone selection buttons stop their emission to give preference to SPS 8 microphone It is mandatory to keep it pressed when talking Once the button is not pressed every device go back to its previous state Botón de selección de entrada de audio auxil...

Страница 7: ...buttons that can be programmed One of these buttons is set by default to actívate the 8 zone selection buttons The program and function assignment for each button can be made in two different ways depending on the requirements 1 Basic To program a preset button to select several zones For this users have to select the zone that they want to use through the zone selection buttons from 1 to 8 Once t...

Страница 8: ...ble in order to program one or more actions In the following updates it will be possible to configure the buttons as Push to work as a push button or Toggle to work as a switch SPS 8 s preset buttons can be configured to interact with different components of an installation from turning on and off the lighting to start an alarm or open a door ...

Страница 9: ...hich are connected to the network When users place the mouse over SPS 8 they can see up to 3 different icons It indicates that the devices is not updated Clicking on this icon users will add the device to the Project It has to be taken under consideration that if the device is not updated it can t be added to the Project i When users place the mouse over this icon it will be shown information abou...

Страница 10: ...n of the BlueLine devices it is recommended to update all of them to the latest version with bug fix and new functionalities The steps to take in the update of a devices are 1 Start WorkCAD and go to the Network tab where we will find every BlueLine devices available on the network 2 When moving the mouse over the name of the device if the icon is shown we should update the device ...

Страница 11: ...the icon if shown in order to update the device If selecting Yes you see an error message please check that the IP range of the PC and the WorkCAD is the same tan the BlueLine device that you mean to update SPS 8 ...

Страница 12: ...isconnect the device until the process has ended 6 When the update is eneded WorkCAD will show a message informing that the process has been done successful Change the name of a SPS 8 with WorkCAD 1 To change the name of a device it is necessary to add it to the Project clicking on the icon of the Network tab The device will be add to the Project Inspector window of the project ...

Страница 13: ...2 Right click on the name of the device Select Rename from the list of option that will be shown ...

Страница 14: ...ess of a device has been changed it is highly advisable to restart the device to correctly save the data Change the IP address of a SPS 8 with WorkCAD 1 Right click on the name of the device Select Change static IP from the list of option that will be shown ...

Страница 15: ... it is advisable to restart the device in order to save the data correctly Restart of a SPS 8 from WorkCAD 1 Right click on the name of the device Select RebootDevice from the list of option that will be shown 2 WorkCAD will ask users for a confirmation to restart the device ...

Страница 16: ...e to adjust the broadcast channel by introducing a specific channel number Zone selection By default every emitter of BlueLine Digital System belong to zone 1 If you want to change the emitter of the zone keep in mind that zone 0 and zone 1 are taken for Broadcast and Receivers respectively Assignment of functions to each zone and preset selection Button From the menu Zone Presets it is possible t...

Страница 17: ...t to assign an specific function to 2º We choose whether the command will be triggered on activate or deactivate 3º Set the IP address of the device we want to send the message to If we want to send a message to the whole network we should introduce 255 255 255 255 ...

Страница 18: ...II that we want to send Keep in mind that WorkCAD incorporates an OSC to ASCII tool in case you need to check any command Once the command is written click over Add and then Apply the changes Ajuste del tipo de codificación Users can adjust the type of coding according to the requirements of the installation For that it is possible to choose PCM ADPCM and MP3 ...

Страница 19: ...on is actívate the station will work then as sender broadcasting seamless the source connected to the AUX IN input For more information please check the AUX button section of this presentation Priority configuration When an installation requires 2 or more SPS 8 it is necessary to set and assign priorities For that before the installation each paging station should be connected to a PC and through ...

Страница 20: ...nced functions when the activation of the alarm is done thus beside triggering the channel priority it is possible to trigger other commands to interact with doors signals sirens The command and function management to the alarm port is done through WorkCAD It is possible to add these commands using the alarm configuration menu The alarm works as the 4 preset buttons with the exception that it is t...

Страница 21: ...hese keys virtually using the 4 Preset keys as a paging mode being able to have access to the selection of up to 32 zones The steps to follow are those 1 Select the preset key 2 Select the preset key that we want to configure as Paging between pages of zones In the IP field we introduce 127 0 0 1 and in the Port field we enter 9000 ...

Страница 22: ...sps8 zonePage i page number Page number 1 to select the zones 1 8 a To select zone 9 16 b To select zone 17 24 c To select zone 25 32 Press Add to add the command 5 We turn on the Led of the selected preset with the command sps8 selectPreset page number i 1 número de página 1 To iluminate the preset led 1 2 To iluminate the preset led 2 3 To iluminate the preset led 3 4To iluminate the preset led ...

Страница 23: ...ed number of pages here it is indicated to choose between the first four pages however it is possible to configure an SPS8 for zones 1 32 and another SPS8 for zones 33 64 and so on Ding Dong sound emission setting at startup The SPS 8 can generate a Ding Dong before sending the message The microphone will not be operational until the melody is finished Once the melody is finished you can start the...

Страница 24: ...ult when the user releases the Push to Talk button after the message the selected zone is cleared leaving the SPS8 clean for a new selection It is possible to configure the SPS8 to keep the selected zone always even after releasing the Push to Talk button To do this check the box Keep Zone selection After Talking ...

Страница 25: ...fault the button behaves like a Push button which means that the user must hold the button pressed to speak It is possible to configure the Push to Talk button to behave like Toggle which means that after pressing the button once the microphone will remain active until the Push to Talk is pressed again ...

Страница 26: ...EQUIPSON S A Avda El Saler 14 Pol Ind L Alteró 46460 Silla Valencia Spain Tel 34 961 216 301 Fax 34 961 200 242 www work es support work es ...

Отзывы: