background image

Loudspeaker Connection 

Note: Use only 100V or 70V (Selectable) Line Loudspeakers 

Two loudspeaker outputs are provided. The output marked ‘Music/speech gives an output at all times, 
reproducing any signal input into the amplifier. The output marked ‘Speech Only’ will only reproduce a 
signal during a priority condition, therefore an output from this connection will be present when 
Microphone is in a priority condition. this means that only the ‘Ding Dong’ chime and the signal from one 
of these microphone inputs will be presented to this output. 

 

Low Impedance (8

O

This output allows connection of standard low impedance loudspeakers, the minimum load impedance 
must be 8

O

, when two or more loudspeakers are use ensure that they are wired in such a way that the 

load impedance is between 8

O

 and

 

16

O

 

Connecting a Mixer Amplifier to a Power Amplifier 

These amplifier can be connected using phono to phono leads from the mixer amplifier PRE out to the 
power amplifier input phono socket. further power amplifier Can be connected by connecting from the 
output of first power amplifier to the input of the second. up to three power amplifier can be connected in 
this way. 

   If the Two Zone feature is required. the manual priority terminals must be used. connecting the priority 

terminals from the mixer amplifier to the first power amplifier. up to three power amplifier can be 
connected in this way. 

 

VC A noise gate 

 

The mixer amplifier are equipped with a VOX in master section. The input level which is required to 

open the noise gate (S601 on the VR PCB-fixed on the front panel). When using the noise gate ( on ) 

then the S/N ratio can get more than 75dB for MIC inputs and 80dB for  Aux / CD inputs. 

Power amplifier setting 

SW401

100mV

500mV

1V

SW403

SW404

PAB-1

 

l

 

Input Sensitivity Setting

 

        

The amplifier has three ( 1V, 500mV, 100mV) Selectable input Sensitivity located on the PCB (SW401). 

The sensitivity of amplifier are factory Set to 500m V. 

l

 

Amplifier Settings (connecting more power amplifiers)

 

(mode selector switch located on the PCB) 

    

(SW403)         (SW404)    

    (AMPLIFIER)  

       

      

STAND ALONE  

       

      

MASTER   

       

      

SLAVE 

     

Single unit operation 

        

For single unit operation, set the mode selector switch (SW403,SW404) Located on the PCB to 

the “ STAND ALONE” position.  

     

Three unit operation 

         For

 two or three unit operation, one unit must be  designated the master unit, this can be done by 

the mode selector switch to the “ MASTER “ position.  All  other units must be switched to “SL AVE” 
mode.   

 

FRONTAL

PANEL

Amplificador Mezclador de 2 Zonas

 

1. Mic1

 Control de volumen

 

7. Master 

Control de tonos(Graves)

 

2. Mic2

 

8. Master 

Control de tonos (Agudos)

 

3. Mic3

 

9. Master  Control de volumen

 

4. Mic4

 

10.Interruptor de red

 

5. Line

 

11. LED indicador de red

 

6.Selector CD/Aux

 

12.LED indicador de nivel de salida

 

 

 

PANEL TRASERO

 

 

 

COM     8        100V    COM    100V

 DC 24V

PRE OUT

MIC  2

MIC  1

SENS VR

MONITOR  OUTPUT

TEL/EMER

SENS VR

MIC  4

MIC  3

MUSIC/SPEECH

LINE FUSE

Connected for 230v~

Apparatus  delivered 

115V~

230V~

600         1V

     8     1W

~       0       ~

+        P

MIC

MIC

LINE

LINE

PHANTOM

PHANTOM

+

19

20

18

22

23

28

5

6

7

8

9

10

11

12

14

13

15

16

17

25

27

21

24

26

29

 

 

1.

 

2.

 

3.

18.

 

4.

19.

 

5.

20.

 

6.

21.

7.

8.

9.

Tornillo de conexión a tierra

Terminales de alimentación DC

Terminales de salida de altavoz

Entrada Power (RCA phono)

Salida Tape ( 2x RCA phono)

Entrada CD (2x RCA phono)

Entrada MIC4 (XLR balanceado)

Portafusible de red

Selector de red 115/220V

Conector de red

Salida Pre (RCA phono)

MIC3, selector Line/Phantom/Mic

Terminales de prioridad

Terminales de entrada TEL/EMER

Terminales de salida de monitor

Control de nivel de salida de monitor

Control de nivel de entrada TEL/EMER

Conmut. On/off de la sirena

16.

17.

22.

23.

24.

25.

26.

27.

28.

29.

10.

11.

12.

13.

14.

15.

Entrada AUX (2x RCA phono)

Entrada MIC4 (DIN balanceado)

Entrada MIC3 (XLR balanceado)

Entrada MIC3 (DIN balanceado)

Entrada MIC2 (XLR balanceado)

Entrada MIC2 (DIN balanceado)

MIC4, selector Line/Phantom/Mic

Entrada MIC1 (XLR balanceado)

Entrada MIC1 (DIN balanceado)

Entrada MIC2 Control sensibilidad

Entrada MIC1 Control sensibilidad

 Control de volumen

 Control de volumen

 Control de volumen
 Control de volumen

2

3

4

5

6

7

8

9

10

11

12

1

7                                                                                                                                   10

Содержание PA 120/2 PRO

Страница 1: ...User Manual Instrucciones de Usuario Equipson S A www equipson es support equipson es PA 120 2 PRO...

Страница 2: ...r in the plug or at the distribution board Tipo Amplificador mezclador de dos zonas Modelo PA 120 2 PRO Alimentaci n AC115V 230V 50 60Hz 10 Conmutable Alimentaci n Bateria DC 24V 10 desviaci n max 180...

Страница 3: ...marcada como Music Speech lleva siempre la salida reproduciendo cualquier se al que entre en el amplificador La salida marcada Speech only reproduce s lo una se al durante la condici n de prioridad as...

Страница 4: ...umen situado en el panel trasero no puede ser configurado a 0 La entrada de emergencia tiene la prioridad m s alta todas las otras entradas tendr n menor rango de prioridad Conexi n de la salida de mo...

Страница 5: ...ceado y de conector XLR situados en el panel trasero con alimentaci n phantom seleccionable Cablee los conectores de la siguiente manera XLR Funcionamiento Balanceado PIN1 Malla PIN2 Se al vivo PIN3 S...

Страница 6: ...ive Pin2 GND Pin3 Signal Return Pin4 Priority Control Pin5 GND 1 4 Stereo Jack Plug Balanced operation Tip Signal live Ring Signal Return Sleeve Screen Priority Microphone Mic1 input has VOX priority...

Страница 7: ...anticlockwise to reduce the volume The Aux CD input sockets are standard RCA phono two sockets are supplied and these are linked together internall y this allows stereo signal source to be used witho...

Страница 8: ...00mV l Amplifier Settings connecting more power amplifiers mode selector switch located on the PCB SW403 SW404 AMPLIFIER STAND ALONE MASTER SLAVE Single unit operation For single unit operation set th...

Страница 9: ...r Mic1 Mic2 Mic3 Mic4 Aux CD 6 5 4 3 2 1 Priority level Using for priority screw terminal Tel Emer Mic1 Mic2 Mic3 Mic4 Aux CD 6 2 2 2 2 1 Dimentions H W D 88 430 300 mm Weight Approx 10 kg Color Black...

Отзывы: