22

Text Display

6 720 610 598 GB (03.11)

B

Confirm the selection by pressing the 

 button.

The corresponding submenu is displayed:

Fig. 10

Submenu: Time/day

In the submenus, the top line indicates what action is required.
The bottom line shows the previous menu level, if applicable (see 
Fig. 10).

B

Use the 

 or 

 button to select 

Time/day

.

B

Confirm the selection by pressing the 

 button.

The corresponding submenu is displayed:

Fig. 11

Setting the hour

When settings are being entered, the setting to be altered is indi-
cated on the top line. In addition, the setting being altered is dis-
played with a dark background.

B

Use the 

 or 

 button to set the hour.

– Press and release to change the display by one unit at a 

time

– Press and hold to change the display rapidly

B

Confirm the setting by pressing the 

 button.

6 720 610 598-05.2O

T

6 720 610 598-06.2O

T

H

Содержание R 30 HE plus combi

Страница 1: ...0 35 40 HE plus combi Wall mounted condensing boiler for central heating and mains fed domestic hot water ZWBR 7 30 R 30 HE plus GC Number 41 311 79 ZWBR 11 35 R 35 HE plus GC Number 41 311 80 ZWBR 11...

Страница 2: ...water immediately 29 6 7 i Info 29 6 8 Settings 30 6 8 1 Heating if TR 2 is connected 30 6 8 2 Hot Water Storage Tank system models only 30 6 8 3 Service 30 6 9 Individual timer programmes 30 7 Indivi...

Страница 3: ...f chemically aggressive substances e g halogenated hydrocarbons which contain chlorine or fluorine compounds This will prevent corrosion Instructions to the customer B Explain to the customer how the...

Страница 4: ...mission appliances Multi function display Bosch Heatronic control system with integrated text display for service functions and faults 3 channel digital timer for one heating circuit Variable pump Aut...

Страница 5: ...Temperature Controller 1 5 Casing dimensions Fig 1 13 Manifold assembly 101 Outer case 103 Facia cover X Standard Concentric Horizontal Flue System min 160 mm Alternative Concentric Flue System min 2...

Страница 6: ...H flow 63 Adjustable gas flow restrictor 64 Adjusting screw for min gas flow volume 88 3 way valve combi 98 DHW flow switch combi 102 Inspection window 120 Fixing points 221 1 Flue duct 221 2 Combusti...

Страница 7: ...s 46 Cold water inlet 47 CH return 52 Solenoid valve 1 52 1 Solenoid valve 2 55 Filter 56 Gas valve CE 427 57 Main valve disc 61 Reset button 63 Gas flow restrictor adjustable for max gas flow volume...

Страница 8: ...AC 230 V 153 Transformer 161 Link 226 Fan 300 Code plug 302 Earth connection 310 Temperature control for hot water 312 Fuse slow T 1 6 A 313 Fuse slow T 0 5 A 317 Digital display 328 Terminal block f...

Страница 9: ...ications Hot water flow rate 35 rise l min 12 1 12 1 14 6 14 6 16 4 16 4 Outlet temperature range C 40 60 40 60 40 60 40 60 40 60 40 60 Max permissible water supply pressure bar 10 10 10 10 10 10 Min...

Страница 10: ...input not exceeding 70 kW net Flues BS 5440 2 Flues and ventilation for gas appliances of rated input not exceeding 70 kW net Air Supply BS 6891 Installation of low pressure gas pipework installation...

Страница 11: ...ice at the point of the flexible hose connections Over rim bidets may be connected to the appliance pro vided that it is in accordance with the requirements of the local water company The outlet s sho...

Страница 12: ...6 3 4 Siting the appliance Regulations concerning the Installation Site B Relevant national regulations must be complied with section 3 9 1 B Consult the installation instructions for details of min...

Страница 13: ...the wall mounting frame to the wall with the screws provided B Mark the position of the flue duct hole if a rear flue is to be used Refer to fig 1 and 16 Fig 8 B Screw the pre plumbing manifold with...

Страница 14: ...d with a downward slope of at least 2 5 3 7 Fitting the appliance Removing the outer case B Remove retaining screws 1 see Fig 13 B Slide the outer case upwards and forwards to remove 2 Fig 13 Boiler B...

Страница 15: ...pipe 3 9 Flue Systems The only flue systems that may be used are those sup plied with the boiler The flue system must be installed in accordance with the requirements of BS5440 1 Standard 100 mm flue...

Страница 16: ...I I boundary Q K H H A F J P Dimension Terminal position kW input expressed in net Balanced flues room sealed Fanned draught A1 Directly below an opening air brick opening windows etc 300 mm B1 Above...

Страница 17: ...s for fitting other flue systems are packed with the relevant flue kit Check that the position chosen for the appliance is sat isfactory Refer to fig 16 Fig 16 Marking the position of a side flue open...

Страница 18: ...assembly Measure the flue length L Refer to fig 21 22 Maximum 1600mm Clamp Flue Turret Terminal Assembly Outer Wall 6 720 610 599 00 TD Extension Duct Clamp Flue Turret Terminal Assembly Outer Wall 6...

Страница 19: ...solvent free grease is lightly applied i e Silicone lubricant to the male end of the ducts NOTE An inner wall sealing plate is provided which should be fitted to the ducts before assem bly Push the a...

Страница 20: ...electrical supply Water Protection IPX4D 4 1 Connecting the appliance To gain access to the mains connection remove the drop down facia cover The drop down cover is removed by lowering it to the hori...

Страница 21: ...beneath the Text display page 8 fig 4 item 422 using a minimum 1mm cable to avoid incresing resistance between the terminals see Fig 29 Fig 29 4 3 Mains Voltage external controls connections Externall...

Страница 22: ...tral heating system should be flushed in accordance with the guidelines given in BS7593 1992 Treatment of water in domestic hot water systems Full instructions are supplied with proprietary cleansers...

Страница 23: ...ap filling programme ensures that the condensa tion trap is filled after the appliance has been installed or after the appliance has been out of use for a long period or the mains supply has been inte...

Страница 24: ...pproximately 2 l min B To increase the flow rate turn screw on flow switch anti clockwise The outlet temperature will decrease relative to the increase in the flow rate B To reduce the flow rate min 8...

Страница 25: ...press any button e g The display lighting switches on and the main menu is displayed Fig 36 Main menu B Use the or button to move the cursor arrow on the left of the menu so that it points to the des...

Страница 26: ...following message is displayed Please wait Initialising 6 3 Menu structure i The hours of service can not be reset to 0 C C C Submenu Main menu 1 2 3 Parameters to change select Page Time day holi da...

Страница 27: ...Frost protection Same times for Monday to Friday Same times for Saturday and Sunday Different times for every day Setting switching times and operating mode B From the main menu select Heating and the...

Страница 28: ...imer programme enabling Hot Water pre heat from 5 00am disabling Hot Water preheat from 10 00pm The ECO button must not be lit 6 7 i Info B Select Info from the main menu You can view the following in...

Страница 29: ...the third submenu select Language B Press or to select the desired language Two other supplementary functions can be selected from the third submenu Language Time correction LCD contrast Time correcti...

Страница 30: ...eneral description The text display module provides a convenient means of setting various appliance functions This description is limited to those functions necessary for commissioning Displaying serv...

Страница 31: ...between min rated heat output and max rated heat output to limit it to the specific heat requirements The factory setting is the max rated heat output 100 B Look up heating output in kW and correspon...

Страница 32: ...ch I B Unscrew sealing plug from flue gas testing point 234 Refer to fig 40 B Insert testing probe about 135 mm into the flue gas testing point and seal testing point Fig 40 B On the text display unit...

Страница 33: ...on B Remove testing probe from the flue gas testing point 234 and refit sealing plug B Re seal gas valve adjusting screw and gas flow restrictor B Replace the outer case by locating it on the top lugs...

Страница 34: ...active The button will light up and the display shows the CH flow temperature B Remove sealing plug from flue gas testing point 234 fig 43 B Insert testing probe about 135 mm into the testing point an...

Страница 35: ...stance to earth Replace the text display module or the Heatronic PCB If the text display module is replaced the service func tion settings are retained B The remaining settings have to be re entered I...

Страница 36: ...page 34 6 Check CO2 setting for min max gas air ratio see page 32 min max 7 Check gas and water systems for leaks see page 15 8 Check hot water outlet temperature see page 37 9 Check heat exchanger se...

Страница 37: ...anger and replace B Before removing the heat exchanger shut the inlet valve and drain the hot water circuit B Use new seals when replacing the heat exchanger Fig 44 Primary Heat exchanger There is a s...

Страница 38: ...ue of approx 5 Nm Burner B Check that the gas cock is turned off and the master switch is in the OFF position B Remove the clips 1 and unscrew the two bolts 2 Refer to fig 50 B Unscrew and remove the...

Страница 39: ...assembly taking care not to mislay the inspection window Diaphragm in mixer unit for 30 HE plus B Open mixer unit 29 B Carefully withdraw diaphragm 443 from fan intake tube and check for soiling and...

Страница 40: ...ystem does not retain the pressure the expan sion vessel and the heating system should be checked for leaks 9 3 Replacement of Parts Before changing any components check that the gas is turned off and...

Страница 41: ...connector has a positive clip fixing B Remove fixing screws attaching fan to the burner cover 3 B Remove fan together with gas pipe and mixer unit B Separate the fan from the pipe and mixer unit by t...

Страница 42: ...lve Fig 59 After refitting B Fill system bleed and re pressurise see Installation Instructions 9 3 5 3 way diverter valve motor B Switch off the appliance B Turn off the service cocks B Unplug connect...

Страница 43: ...d in section 8 1 Fig 60 9 3 8 Domestic Hot Water Heat Exchanger B Refer to section 9 2 B Use new seals when fitting the new heat exchanger 9 3 9 Electrode assembly B Refer to section 9 2 B Use a new s...

Страница 44: ...urner Refer to section 9 2 B Disconnect the sensors Refer to section 9 3 6 B Undo the central heating flow union B Undo the top connection of the pump Refer to fig 57 B Undo the grey plastic cap next...

Страница 45: ...connecting lead E9 Safety temp limiter in CH flow has tripped Check system pressure check safety temp lim iters check pump operation check fuse on pcb bleed appliance EA Flame not detected Is gas cock...

Страница 46: ...lve 1 8 717 401 012 0 10 Electrode assembly 1 8 718 107 077 0 11 Electrode lead 1 8 714 401 999 0 12 Pump 1 8 717 204 350 0 13 Pressure gauge 1 8 717 208 079 0 14 Burner skin seal 1 8 711 004 168 0 15...

Страница 47: ...37 4 80 24 2 24 4 42 7 90 27 2 27 5 48 0 100 30 2 30 5 53 4 Table 20 Propane Display code Heat output kW Heat input kW 40 12 1 12 2 50 15 1 15 3 60 18 1 18 3 70 21 1 21 4 80 24 2 24 4 90 27 2 27 5 10...

Страница 48: ...ter temperature is 8 C above set value NOTE The appliance controls can be set to one of 2 modes of operation 1 Comfort mode Full pre heat 2 ECO mode a Operates as an instantaneous combination boiler b...

Страница 49: ...mp ON Fan to start speed Gas valve opens Burner stabilises at start speed for 5 10 secs Fan speed reduces over 15 secs Fan min speed for 90 secs Boiler unused for long period Minimum heat input for 15...

Страница 50: ...6 720 611 400 GB 03 11 50 Appendix...

Страница 51: ...6 720 611 400 GB 03 11 Appendix 51...

Страница 52: ...Appendix Appendix EXCELLENCE COMES AS STANDARD Worcester Bosch Cotswold Way Warndon Worcester WR4 9SW Telephone 01905 754624 Fax 01905 754619...

Страница 53: ...and Customer Care Guide R 30 35 40 HE combi plus Condensing boiler 6 720 610 598 00 2O ZWBR 7 30 R 30 GC Number 47 311 79 ZWBR 11 35 R 35 GC Number 47 311 80 ZWBR 11 40 R 40 GC Number 47 311 81 6 720...

Страница 54: ...15 3 5 Combination Boilers Setting Hot Water Temperature 16 3 6 System boiler with Storage Tank 17 3 7 Summer Mode Hot Water Only Combi Appliances 18 3 8 Frost protection Combi Appliances 19 3 9 Faul...

Страница 55: ...mediately System models 31 4 7 i Info 32 4 8 Settings 33 4 8 1 Heating if TR 2 is connected 33 4 8 2 Hot Water Storage Tank System boiler models only 33 4 8 3 Service 33 4 9 Individual timer programme...

Страница 56: ...Worcester Heat Systems Ltd Offering a complete maintenance scheme to keep your boiler operating at peak condition and efficiency No wonder that more and more people are agreeing that when it is gas i...

Страница 57: ...doors and windows B Do not operate any electrical switches B Do not smoke B Extinguish any naked flames B Call your gas company If you smell fumes from the appliance B Switch off appliance B Open wind...

Страница 58: ...no potential hazard due to the appliance being electri cally unsafe B There are no substances used in the construction that are a potential hazard in relation to the COSHH Regulations Con trol of Subs...

Страница 59: ...e being heated at an even rate If the top of a radiator is at a lower temperature than the bottom then it should be vented by releasing air through the venting screw at the top of the radiator Ask you...

Страница 60: ...s Thermostatic radiator valves It is recommended that this type of valve is fitted to all the radiators except one usually the radiator where the room temperature con troller is fitted They should con...

Страница 61: ...appliance will still operate in the central heating mode Use in hard water areas Combination Boilers In exceptionally hard water areas a device to prevent scale forma tion may be fitted Installation...

Страница 62: ...598 GB 03 11 Do not allow the flue terminal fitted on the outside wall to become obstructed or damaged Pump The pump is a fully modulating type to which the parameters have been set by the manufacture...

Страница 63: ...w and return 171 Hot water 172 Gas isolation valve open 173 Cold water inlet 295 Identification sticker 310 Hot water temperature control 317 Display 363 Indicator lamp for burner on 364 Indicator lam...

Страница 64: ...ith direction of flow the cock is open Central heating system valves 170 B Using a spanner turn square nut until groove is in line with direction of flow see detail Groove at right angles to direction...

Страница 65: ...ow 1 bar when the system is cold top up the system with water until the pointer is 1 bar Your installer will have shown you how to do this B The maximum operating pressure of 2 5 bar at maximum centra...

Страница 66: ...res that the condensation trap is filled after the appliance has been installed or after the appliance has been out of use for a long period For that reason the appli ance remains at minimum heating o...

Страница 67: ...etting E approx 75 C Max setting 88 C When the burner is lit the red indicator lamp is illuminated Fig 5 3 4 Controlling Central Heating B Set the timer to the correct time B Set room thermostat to th...

Страница 68: ...on By pressing and holding the ECO button until the display lights you can switch between Comfort mode and Economy mode Comfort mode button is not lit factory setting The appliance is held constantly...

Страница 69: ...e ECO mode button is lit Water is not heated up until hot water is drawn This means that there is a longer waiting period before hot water is available 3 6 System boiler with Storage Tank B Set the ho...

Страница 70: ...e ECO mode button is lit In ECO mode the appliance switches between central heating mode and cylinder charging mode every 12 minutes 3 7 Summer Mode Hot Water Only Combi Appliances With room temperatu...

Страница 71: ...ent of a fault occurring while the appliance is in operation The display and the text display then shows a fault code and the button may also flash If the button flashes B Press and hold the button un...

Страница 72: ...odule has a power buffer period of about 10 hours during which it will run without the mains power supply After that period has elapsed the clock function shuts down but all other settings are retaine...

Страница 73: ...erating modes may be displayed during commis sioning servicing etc The programming procedure is described in detail below using the clock function as an example B To start programming press any button...

Страница 74: ...ime day B Confirm the selection by pressing the button The corresponding submenu is displayed Fig 11 Setting the hour When settings are being entered the setting to be altered is indi cated on the top...

Страница 75: ...other buttons for 15 minutes 4 2 1 Deleting a setting Either over write the setting or press the button to delete it B Find the setting to be deleted B Press and release the button The display shows...

Страница 76: ...ays Days holiday 25 Heating Heating program Day 1st operating mode 1st switching point 6th switching point 27 Set econ omy temp if TR2 is connected 5 30 C 28 Manual if TR2 is not con nected Automatic...

Страница 77: ...ct Holidays B Enter the number of days holiday by pressing or max 99 days holiday After the set number of days the text display module automat Settings Heating Optimum Start Off On 33 Hot water System...

Страница 78: ...mode early B In the Holidays submenu Press the button until the display shows 0 i The day on which you enter the days holiday counts as the first day of the holiday i e the unit starts the holiday pro...

Страница 79: ...urday and Sunday Different times for every day Setting switching times and operating mode B From the main menu select Heating and then from the first submenu select Heating program B Select Monday Fri...

Страница 80: ...o not wish to change can be skipped by pressing 4 5 2 Setting the Economy temperature if TR2 is con nected This option allows you to set the room temperature for Economy mode Off Economy This function...

Страница 81: ...onstant on comfort and Constant off economy The manually selected operating mode starts immediately Constant off economy and Constant on comfort are auto matically reset at 00 00 midnight To cancel th...

Страница 82: ...enabled from 5 00 am disabled from 10 00 pm The ECO button must not be lit Comfort mode System models with Storage Tank The basic settings pro vide a timer programme enable from 5 00 am disable from...

Страница 83: ...ocked Released operating mode in the same way as for the switching points and modes for heating as described on page 27 4 6 2 Hot water immediately System models Hot water immediately ON Comfort mode...

Страница 84: ...for CH flow Actual flow temp Actual CH flow temperature Required flow temp Required CH flow temperature Max HW temp Maximum permissible hot water out flow temperature Required HW temp Required hot wa...

Страница 85: ...se up to six different times with temperatures see page 30 Hot water Only times During that times the Storage Tank will be charged to the chosen temperature B From the main menu select Settings and fr...

Страница 86: ...ction LCD contrast Time correction B Press and hold the button about 5 seconds until the display shows Time correction and LCD contrast B Press or to select Time correction B Press the button The disp...

Страница 87: ...d submenu select Operating times Fault history This option displays any faults that have occurred for the informa tion of the service engineer The first fault displayed may still be active Any other f...

Страница 88: ...Operating mode Time Operating mode Time Operating mode Time Operating mode Time Monday Tuesday Wednesday Thursday Friday Saturday Sunday Enable disable hot water function Switching point 1 2 3 4 5 6 S...

Страница 89: ...tem Desired room temperature exceeded by large amount Radiators are too hot Turn down ther mostatic valves Temperature rises instead of falling Clock is incor rectly set Check setting Room tempera tur...

Страница 90: ...ermostatic radiator valves The central heating control on the boiler should be set to the max imum rated temperature of the central heating system or to posi tion E when the maximum central heating wa...

Страница 91: ...e contact your installer or write to us 7 General Information Cleaning the Outer Case Wipe down the outer case with a damp cloth Do not use abrasive or caustic cleaning agents Appliance details If you...

Страница 92: ...operate at peak efficiency and performance it is essen tial that your boiler receives regular competent servicing and maintenance checks beyond the initial 2 year guarantee period If you would like to...

Страница 93: ...Our Field Service Engineer finds no fault with the appliance see NOTE OR The cause of breakdown is misuse or with other parts of your plumbing heating system or with equipment not supplied by Worceste...

Страница 94: ...ssioned and where appropriate the first 2 year service has been carried out to the satisfaction of Worcester Heat Systems Limited when requested That any product or part thereof returned for servicing...

Страница 95: ...ice by establishing a reference and permanent record for your boiler This will not affect your statutory rights in any way Important For your own record Model Serial number See identity label inside a...

Страница 96: ...ay Set switching times and operating mode within the text display Hot water temperature Combina tion boiler only ECO button lit Economy mode ECO button not lit Comfort mode Fault Condition Refer to pa...

Отзывы: