Product details

6 720 805 339 (2014/09)

5

2.4

Standard delivery

Fig. 1  

[1]

Twin coil DHW cylinder

[2]

Temperature and pressure relief  valve

[3]

Immersion heater, 3 kW

[4]

Tundish Ø 15/22 mm

[5]

Solar high limit thermostat

[6]

Cold water inlet control group with anti-vacuum valve

[7]

2-port valve 

[8]

Dual cylinder thermostat

[9]

DHW expansion vessel incorporating fixing bracket

[10] Connection set
[11] Set of printed documents for the appliance and ErP label

2.5

Scaling/Corrosion protection

The cylinder is made from corrosion-resistant Duplex stainless steel.

The cylinder can be used with all mains water supplies.

Scaling:  In cases where the water hardness is very high (over 450 ppm) 
a water softener must be used to protect the cylinder against rapid 
development of scale.

Corrosion protection:  Any water softener shall be installed, 
commissioned and maintained to ensure the water hardness after the 
softener is never below 150 ppm.

2.6

Description of function

• If there is insufficient heat input available via the primary (lower) coil, 

the secondary heating appliance will heat the upper coil.

• Due to temperature stratification only the upper section of the 

cylinder will be heated. 

• When hot water is being drawn off, the cylinder temperature in the 

upper section drops by approximately 8 °C to 10 °C before the heat 
source reheats the cylinder.

AQU-18-3W

AQU-16-3W

AQU-17-3W

AQU-21-3W

AQU-31-3W

1

4

5

6

7

8

9

10

11

2

3

6 720 645 525-07.4GX

Содержание Greenstore TC Cylinder 150 litre

Страница 1: ...Installation and maintenance instructions Twin Coil Indirect Unvented Hot Water Cylinder Greenstore TC Cylinder Series 6 720 645 525 00 1O 150 180 210 250 300 litre 6 720 805 339 2014 09 UK...

Страница 2: ...appliance 13 3 7 2 Connection of the primary appliance or solar system 13 3 7 3 Connection on the water side 13 3 7 4 DHW secondary circulation 13 3 7 5 DHW expansion vessel 14 3 7 6 Installing the d...

Страница 3: ...st install commission and maintain this equipment Only use the cylinder for heating domestic hot water Function Observe these installation and maintenance instructions to ensure correct operation Neve...

Страница 4: ...nput reduces the cycling of the heating appliance and reduces the cylinder heat up time 2 2 Intended use Only use the cylinder for heating domestic hot water Any other application will be considered i...

Страница 5: ...ling Incaseswherethewaterhardnessisveryhigh over450 ppm a water softener must be used to protect the cylinder against rapid development of scale Corrosion protection Any water softener shall be instal...

Страница 6: ...10 Cylinder flow return primary appliance solar 22 mm Fig 3 Physical and connection dimensions AQU 24 3W 6 1 2 2 3 4 5 7 7 8 9 10 10 J 45 35 25 45 AQU 25 3W I B F G H E C D A 15 Cylinder Part number...

Страница 7: ...Product details 6 720 805 339 2014 09 7 clearance dimensions Fig 4 Recommended minimum wall clearances all dimensions in mm 80 6 720 645 525 06 1O 50 50 50 180...

Страница 8: ...9 3 9 Heat exchanger surface m2 0 657 0 657 0 845 0 845 0 845 Maximum heating water temperature C 120 120 120 120 120 Maximum operating pressure inside the upper indirect coil bar 6 6 6 6 6 Heat exch...

Страница 9: ...re of 55 45 frost protection down toapproximately 30 C thepressuredropisapproximately1 3times the value for tap water Fig 5 TC 150 and TC 180 p Pressure drop V Heating water volume Fig 6 TC 210 TC 250...

Страница 10: ...or human consumption Installation BS EN 806 5 2012 Specifications for installations inside buildings conveying water for human consumption Operation and maintenance BS 8558 2011 Guide to the design in...

Страница 11: ...ary heat source SP Solar circuit pump optional accessory SV1 Temperature and Pressure relief valve SV2 Expansion relief anti vac valve G3 kit supplied SWC Terminal box S solar Twin coil cylinder TB So...

Страница 12: ...in the lower section of the cylinder 6 720 645 525 05 1O 2 1 3 Solar thermal system yes yes no no System type S plan or Y plan with internal three way valve S plan or Y plan with internal three way v...

Страница 13: ...ockattimeofcommissioning the unit an air vent may be required The coil must be able to be drained via a suitable valve 3 7 3 Connection on the water side Install the cold water inlet control group as...

Страница 14: ...etydeviceunlessitstotalequivalenthydraulicresistanceexceeds that of a straight pipe 9 m long i e discharge pipes between 9 m and 18 m equivalent resistance length should be at least two sizes larger t...

Страница 15: ...herefore calculate the next largest size Maximum resistance allowed for a straight length of 28 mm copper discharge pipe D2 from a G1 2 temperature relief valve is 18 m Subtract the resistance for 4 N...

Страница 16: ...diagrams reference must be made to the appropriate manufacturers installation instructions for the products installed along side this unit Products must be wired to meet all current regulations with...

Страница 17: ...MUST incorporate a gravity break check valve G3 protection from excessive solar input Additional wiring for solar pump stations without a gravity break check valve A solar high limit thermostat will i...

Страница 18: ...g 15 Greenstar i System Compact wiring example ST10 DIVERTER VALVE MOTOR PLUG CYLINDER TEMPERATURE SENSOR SUPPLIED IN DIVERTER KIT F1 F3 F2 ST10 ST6 LEAVE LINK Greenstar CDi Classic System boiler ONLY...

Страница 19: ...ofthe immersion heater to complete the wiring Fig 16 Wiring diagram E Earth Green Yellow N Neutral Blue L Live Brown Fig 17 Rigid cable end preparation E Earth Green Yellow N Neutral Blue L Live Brown...

Страница 20: ...solar controller Whenthereisariskoffrostandthecylinderistakenoutofuse drain the cylinder completely including its lower section 5 2 Draining the cylinder To drain either the domestic water system or t...

Страница 21: ...ng or repair Vent the heating solar and DHW sides 8 Spare parts list 9 The Guarantee The Greenstore stainless steel cylinder carries a fully transferable 25 year guarantee against faulty material or m...

Страница 22: ...pressure relief valve and expansion valve been tted and discharge tested Yes No The tundish and discharge pipework have been connected and terminated to Part G of the Building Regulations Yes Are all...

Страница 23: ...er Name Company Name Telephone No Gas Safe Register No Comments Signature Date Engineer Name Company Name Telephone No Gas Safe Register No Comments Signature Date Engineer Name Company Name Telephone...

Страница 24: ...59 Worcester Bosch Group is a brand name of Bosch Thermotechnology Ltd worcester bosch co uk 6 720 805 339 WORCESTER BOSCH GROUP TECHNICAL SUPPORT 0330 123 3366 APPOINTMENTS 0330 123 9339 SPARES 0330...

Отзывы: